Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

GOT1 ELISA Kit

Small Sample GOT1 Reactivity: Mouse Colorimetric Sandwich ELISA 1.56 ng/mL - 100 ng/mL Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
Catalog No. ABIN7012855
  • Target See all GOT1 ELISA Kits
    GOT1 (Glutamic-Oxaloacetic Transaminase 1, Soluble (Aspartate Aminotransferase 1) (GOT1))
    Reactivity
    • 6
    • 5
    • 4
    • 4
    • 3
    • 3
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    Mouse
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    1.56 ng/mL - 100 ng/mL
    Minimum Detection Limit
    0.312 ng/mL
    Application
    ELISA
    Purpose
    The kit is a small sample sandwich enzyme immunoassay for in vitro quantitative measurement in various sample types.
    Sample Type
    Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of Aspartate Aminotransferase.
    Sensitivity
    0.55 ng/mL
    Grade
    Small Sample
    Components
    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • Reagent Diluent (if Detection Reagent is lyophilized)
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30 x concentrate)
    • Instruction manual
    Top Product
    Discover our top product GOT1 ELISA Kit
  • Sample Volume
    25 μL
    Assay Time
    3 h
    Plate
    Pre-coated
    Protocol
    1. Prepare all reagents, samples and standards,
    2. Add 25μL standard or sample to each well. Incubate 1 hours at 37 °C,
    3. Aspirate and add 25μL prepared Detection Reagent A. Incubate 1 hour at 37 °C,
    4. Aspirate and wash 3 times,
    5. Add 25μL prepared Detection Reagent B. Incubate 30 minutes at 37 °C,
    6. Aspirate and wash 5 times,
    7. Add 25μL Substrate Solution. Incubate 10-20 minutes at 37 °C,
    8. Add 20μL Stop Solution. Read at 450nm immediately.
    Reagent Preparation
    1. Bring all kit components and samples to room temperature (18-25 °C) before use. If the kit will not be used up in one time, please only take out strips and reagents for present experiment, and leave the remaining strips and reagents in required condition.
    2. Standard - Reconstitute the Standard with 0.5 mL of Standard Diluent, keep for 10 minutes at room temperature, shake gently (not to foam). The concentration of the standard in the stock solution is 20ng/mL. Prepare 7 tubes containing 0.25 mL Standard Diluent and produce a double dilution series by transferring 250 µL each. Mix each tube thoroughly before the next transfer. Set up 7 points of diluted standard such as 20ng/mL, 10ng/mL, 5ng/mL, 2.5ng/mL, 1.25ng/mL, 0.625ng/mL, 0.312ng/mL, and the last microcentrifuge tube with Standard Diluent is the blank as 0ng/mL.
    3. Detection Reagent A and Detection Reagent B - If lyophilized reconstitute the Detection Reagent A with 150μL of Reagent Diluent, keep for 10 minutes at room temperature, shake gently (not to foam). Briefly spin or centrifuge the stockDetection A and Detection B before use. Dilute them to the working concentration 100-fold with Assay Diluent A and B, respectively.
    4. Wash Solution - Dilute 10 mL of Wash Solution concentrate (30x) with 290 mL of deionized or distilled water to prepare 300 mL of Wash Solution (1x).
    5. TMB substrate - Aspirate the needed dosage of the solution with sterilized tips and do not dump the residual solution into the vial again.

    Note:

    1. Making serial dilution in the wells directly is not permitted.
    2. Prepare standard within 15 minutes before assay. Please do not dissolve the reagents at 37 °C directly.
    3. Please carefully reconstitute Standards or working Detection Reagent A and B according to the instruction, and avoid foaming and mix gently until the crystals are completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10μL for once pipetting.
    4. The reconstituted Standards, Detection Reagent A and Detection Reagent B can be used only once.
    5. Prepare Substrate working Solution within 15 minutes before assay.
    6. If crystals have formed in the Wash Solution concentrate (30x), warm to room temperature and mix gently until the crystals are completely dissolved.
    7. Contaminated water or container for reagent preparation will influence the detection result.
    Sample Preparation
    • It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturation may occur in these samples, leading to false results. Samples should therefore be stored for a short period at 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thaw cycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged to remove precipitates.
    • If the sample type is not specified in the instructions, a preliminary test is necessary to determine compatibility with the kit.
    • If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibility of causing a deviation due to the introduced chemical substance. The recommended dilution factor is for reference only.
    • Please estimate the concentration of the samples before performing the test. If the values are not in the range of the standard curve, the optimal sample dilution for the particular experiment has to be determined.
    Assay Precision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level of target were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level of target were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV < 10%
    Inter-Assay: CV < 12%
    Restrictions
    For Research Use only
  • Storage
    4 °C/-20 ° C
    Storage Comment
    1. For unopened kit: All reagents should be stored according to the labels on the vials. The Standard, Detection Reagent A, Detection Reagent B, and 96-well Strip Plate should be stored at -20 °C upon receipt, while the other reagents should be stored at 4 °C.
    2. For opened kits: the remaining reagents must be stored according to the above storage conditions. In addition, please return the unused wells to the foil pouch containing the desiccant and seal the foil pouch with the zipper.
    Expiry Date
    6 months
  • Target See all GOT1 ELISA Kits
    GOT1 (Glutamic-Oxaloacetic Transaminase 1, Soluble (Aspartate Aminotransferase 1) (GOT1))
    Alternative Name
    Aspartate Aminotransferase (GOT1 Products)
    Synonyms
    ASTQTL1 ELISA Kit, GIG18 ELISA Kit, cAspAT ELISA Kit, cCAT ELISA Kit, AST ELISA Kit, ISSD ELISA Kit, NSD ELISA Kit, SD ELISA Kit, SIALIN ELISA Kit, SIASD ELISA Kit, SLD ELISA Kit, xr406 ELISA Kit, CASPAT ELISA Kit, ASPARTATE AMINOTRANSFERASE ELISA Kit, ATAAT ELISA Kit, MATERNAL EFFECT EMBRYO ARREST 17 ELISA Kit, MEE17 ELISA Kit, T26C19.9 ELISA Kit, T26C19_9 ELISA Kit, aspartate aminotransferase ELISA Kit, aatA ELISA Kit, 83.t00021 ELISA Kit, AI789014 ELISA Kit, Got-1 ELISA Kit, Aspat ELISA Kit, Gaspat ELISA Kit, AL022787 ELISA Kit, FABP-pm ELISA Kit, Got-2 ELISA Kit, mAspAT ELISA Kit, ASPATA ELISA Kit, glutamic-oxaloacetic transaminase 1 ELISA Kit, solute carrier family 17 member 5 ELISA Kit, glutamic-oxaloacetic transaminase 1 homeolog ELISA Kit, aspartate aminotransferase ELISA Kit, glutamic-oxaloacetic transaminase 1, soluble ELISA Kit, glutamic-oxaloacetic transaminase 2 ELISA Kit, glutamatic-oxaloacetic transaminase 2, mitochondrial ELISA Kit, GOT1 ELISA Kit, SLC17A5 ELISA Kit, got1.S ELISA Kit, AAT ELISA Kit, aspC ELISA Kit, EHI_006080 ELISA Kit, AST2 ELISA Kit, ast2 ELISA Kit, got1 ELISA Kit, Got1 ELISA Kit, GOT2 ELISA Kit, Got2 ELISA Kit
    Background
    CCAT, AAT, ASAT, SGOT, GOT1, Cysteine transaminase, cytoplasmic, Transaminase A, Aspartate Transaminase 1,Cytoplasmic, Glutamic-Oxaloacetic Transaminase 1,Soluble
    Pathways
    Hepatitis C, Monocarboxylic Acid Catabolic Process, Methionine Biosynthetic Process
You are here:
Support