AGLU ELISA Kit
-
- Target See all AGLU ELISA Kits
- AGLU (alpha-Glucosidase (AGLU))
-
Reactivity
- Human
- Detection Method
- Colorimetric
- Method Type
- Sandwich ELISA
- Detection Range
- 3.12 μU/mL - 200 μU/mL
- Minimum Detection Limit
- 3.12 μU/mL
- Application
- ELISA
- Purpose
- For the quantitative determination of human α-glucosidase concentrations in serum, plasma, tissue homogenates, urine.
- Sample Type
- Plasma, Serum, Tissue Homogenate, Urine
- Analytical Method
- Quantitative
- Specificity
- This assay has high sensitivity and excellent specificity for detection of human α-Glucosidase. No significant cross-reactivity or interference between human α-Glucosidase and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between human α-Glucosidase and all the analogues, therefore, cross reaction may still exist.
- Sensitivity
- 0.78 μU/mL
- Components
-
- Assay plate
- Standard
- HRP-avidin (100 x concentrate)
- Biotin-antibody (100 x concentrate)
- Sample Diluent
- HRP-avidin Diluent
- Biotin-antibody Diluent
- Wash Buffer (25 x concentrate)
- TMB Substrate
- Stop Solution
- Adhesive Strip
- Top Product
- Discover our top product AGLU ELISA Kit
-
-
- Application Notes
- Optimal working dilution should be determined by the investigator.
- Sample Volume
- 100 μL
- Assay Time
- 1 - 4.5 h
- Plate
- Pre-coated
- Protocol
-
- Prepare reagents, samples and standards as instructed.
- Add 100 µL standard or sample to each well. Incubate 2 hours at 37 °C.
- Remove the liquid of each well, don't wash.
- Add 100 µL Biotin-antibody (1x) to each well. Incubate 1 hour at 37 °C.
- Aspirate and wash 3 times.
- Add 100 µL HRP-avidin (1x) to each well. Incubate 1 hour at 37 °C
- Aspirate and wash 5 times.
- Add 90 μL of TMB Substrate to each well. Incubate for 15-30 minutes at 37 °C. Protect from light.
- Add 50 µL Stop Solution to each well. Read at 450 nm within 5 minutes.
- Reagent Preparation
-
- Biotin-antibody (1x) - Centrifuge the vial before opening. Biotin-antibody requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of Biotin-antibody + 990 μL of Biotin-antibody Diluent.
- HRP-avidin (1x) - Centrifuge the vial before opening. HRP-avidin requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of HRP-avidin + 990 μL of HRP-avidin Diluent.
- Wash Buffer (1x) - If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate (25 x) into deionized or distilled water to prepare 500 mL of Wash Buffer (1 x).
- Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 mL of Sample Diluent. Do not substitute other diluents. This reconstitution produces a stock solution of 200 μU/mL. Mix the standard to ensure complete reconstitution and allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions. Pipette 250 μL of Sample Diluent into each tube (S0-S6). Use the stock solution to produce a 2-fold dilution series (below). Mix each tube thoroughly before the next transfer. The undiluted Standard serves as the high standard (200 μU/mL). Sample Diluent serves as the zero standard (0 μU/mL).
- Kindly use graduated containers to prepare the reagent. Please don't prepare the reagent directly in the Diluent vials provided in the kit.
- Bring all reagents to room temperature (18-25 °C) before use for 30 min.
- Prepare fresh standard for each assay. Use within 4 hours and discard after use.
- Making serial dilution in the wells directly is not permitted.
- Please carefully reconstitute Standards according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10 μL for once pipetting.
- Distilled water is recommended to be used to make the preparation for reagents or samples. Contaminated water or container for reagent preparation will influence the detection result.
- Sample Preparation
-
- It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
- If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
- If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
- Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
Note:Serum and plasma samples require a 20-fold dilution into Sample Diluent. The suggested 20-fold dilution can be achieved by adding 15 μL sample to 285 μL of Sample Diluent. The recommended dilution factor is for reference only. The optimal dilution factor should be determined by users according to their particular experiments. - Assay Precision
-
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. - Restrictions
- For Research Use only
-
- Storage
- 4 °C,-20 °C
- Storage Comment
- Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date. May be stored for up to 1 month at 2 - 8°C. Coated assay Try to keep it in a sealed aluminum foil bag, plate and avoid the damp. Standard May be stored for up to 1 month at 2 - 8° C. If Biotin-antibody don't make recent use, better keep it store at HRP-avidin -20°C. Biotin-antibody Diluent Opened kit HRP-avidin Diluent Sample May be stored for up to 1 month at 2 - 8°C. Diluent Wash Buffer TMB Substrate Stop Solution *Provided this is within the expiration date of the kit.
- Expiry Date
- 6 months
-
- Target See all AGLU ELISA Kits
- AGLU (alpha-Glucosidase (AGLU))
- Alternative Name
- maltase-glucoamylase (alpha-glucosidase) (AGLU Products)
- Synonyms
- MG ELISA Kit, MGA ELISA Kit, SPAC56F8.01 ELISA Kit, SPAC922.02c ELISA Kit, CG11909 ELISA Kit, CT33098 ELISA Kit, Dmel\\CG11909 ELISA Kit, GB19017 ELISA Kit, 6030407P20Rik ELISA Kit, maltase-glucoamylase ELISA Kit, alpha-glucosidase (predicted) ELISA Kit, alpha-glucosidase ELISA Kit, glucosidase, alpha, acid ELISA Kit, target of brain insulin ELISA Kit, sucrase-isomaltase ELISA Kit, MGAM ELISA Kit, SPAC30D11.01c ELISA Kit, LMOf2365_0194 ELISA Kit, SPAC1039.11c ELISA Kit, Gaa ELISA Kit, tobi ELISA Kit, SI ELISA Kit, Hbg3 ELISA Kit, Mgam ELISA Kit
- Background
-
Abbreviation: MGAM
Alias: MG, MGA, alpha-glucosidase|brush border hydrolase|maltase-glucoamylase
- UniProt
- O43451
- Pathways
- Cellular Glucan Metabolic Process
-