Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

SOD1 ELISA Kit

SOD1 Reactivity: Fish Colorimetric Competition ELISA 1.25 ng/mL - 20 ng/mL Plasma, Serum, Tissue Homogenate
Catalog No. ABIN6974208
  • Target See all SOD1 ELISA Kits
    SOD1 (Superoxide Dismutase 1, Soluble (SOD1))
    Reactivity
    • 11
    • 5
    • 5
    • 3
    • 3
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    Fish
    Detection Method
    Colorimetric
    Method Type
    Competition ELISA
    Detection Range
    1.25 ng/mL - 20 ng/mL
    Minimum Detection Limit
    1.25 ng/mL
    Application
    ELISA
    Purpose
    For the quantitative determination of fish superoxide dismutase (SOD) concentrations in serum, plasma, tissue homogenates.
    Sample Type
    Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of fish SOD. No significant cross-reactivity or interference between fish SOD and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between fish SOD and all the analogues, therefore, cross reaction may still exist.
    Sensitivity
    0.625 ng/mL
    Components
    • Assay plate
    • Standard
    • HRP-conjugate (100 x concentrate)
    • Sample Diluent
    • HRP-conjugate Diluent
    • Wash Buffer (25 x concentrate)
    • TMB Substrate
    • Stop Solution
    • Adhesive Strip
  • Stop Solution
  • Adhesive Strip
  • Top Product
    Discover our top product SOD1 ELISA Kit
  • Application Notes
    Optimal working dilution should be determined by the investigator.
    Sample Volume
    50 μL
    Assay Time
    1 - 4.5 h
    Plate
    Pre-coated
    Protocol
    1. Prepare reagents, samples and standards as instructed.
    2. Set a Blank well without any solution.
    3. Add 50 µL standard or sample to each well.
    4. Add 50 µL HRP-conjugate (1x) to each well (Not to Blank well).
    5. Incubate 1 hour at 37 °C
    6. Aspirate and wash 5 times.
    7. Add 90 μL of TMB Substrate to each well. Incubate for 20 minutes at 37 °C. Protect from light.
    8. Add 50 µL Stop Solution to each well. Read at 450 nm within 5 minutes.
    Reagent Preparation
    1. HRP-conjugate (1x) - Centrifuge the vial before opening. HRP-conjugate requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of HRP-conjugate + 990 μL of HRP-conjugate Diluent.
    2. Wash Buffer(1x)- If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate (25 x) into deionized or distilled water to prepare 500 mL of Wash Buffer (1 x).
    3. Standard Centrifuge the standard vial at 6000-10000rpm for 30s before opening. Dilute the Standard(10x) with Sample Diluent. A suggested 10-fold dilution is 30 μL of Standard(10x) + 270 μL of Sample Diluent. This diluted Standard (S5) serves as the high standard (20 ng/mL). Do not substitute other diluents. Mix the standard to ensure complete dilution and allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions. Pipette 150 μL of Sample Diluent into each tube (S0-S4). Use the diluted Standard (S5) solution to produce a 2-fold dilution series (below). Mix each tube thoroughly before the next transfer. Sample Diluent serves as the zero standard (0 ng/mL).
    Note:
    • Kindly use graduated containers to prepare the reagent. Please don't prepare the reagent directly in the Diluent vials provided in the kit.
    • Bring all reagents to room temperature (18-25 °C) before use for 30 min.
    • Prepare fresh standard for each assay. Use within 4 hours and discard after use.
    • Making serial dilution in the wells directly is not permitted.
    • Distilled water is recommended to be used to make the preparation for reagents. Contaminated water or container for reagent preparation will influence the detection result.
    Sample Preparation
    • It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
    • If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
    • If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
    • Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
    Note:
    Recommend to dilute the serum or plasma samples with Sample Diluent (1:200) before test. The suggested 200-fold dilution can be achieved by adding 5 μL sample to 45 μL of Sample Diluent. Complete the 200-fold dilution by adding15 μL of this solution to 285 μL of Sample Diluent. The recommended dilution factor is for reference only. The optimal dilution factor should be determined by users according to their particular experiments. 6
    Assay Precision
    Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess.
    Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess.
    Restrictions
    For Research Use only
  • Storage
    4 °C,-20 °C
    Storage Comment
    Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date. May be stored for up to 1 month at 2 - 8°C. Coated assay Try to keep it in a sealed aluminum foil bag, plate and avoid the damp. Standard May be stored for up to 1 month at 2 - 8° C. If don't make recent use, better keep it store at HRP-conjugate -20°C. Opened kit HRP-conjugate Diluent Sample Diluent May be stored for up to 1 month at 2 - 8°C. Wash Buffer TMB Substrate Stop Solution *Provided this is within the expiration date of the kit.
    Expiry Date
    6 months
  • Target See all SOD1 ELISA Kits
    SOD1 (Superoxide Dismutase 1, Soluble (SOD1))
    Alternative Name
    Superoxide Dismutase(SOD) (SOD1 Products)
    Synonyms
    LOC692639 ELISA Kit, ALS ELISA Kit, ALS1 ELISA Kit, IPOA ELISA Kit, SOD ELISA Kit, hSod1 ELISA Kit, homodimer ELISA Kit, CG11793 ELISA Kit, Cu ELISA Kit, Cu-Zn SOD ELISA Kit, Cu/Zn SOD ELISA Kit, Cu/Zn sod ELISA Kit, Cu/Zn superoxide dismutase ELISA Kit, Cu/ZnSOD ELISA Kit, CuSOD ELISA Kit, CuZn SOD ELISA Kit, CuZn-SOD ELISA Kit, CuZn-SOD1 ELISA Kit, CuZnSOD ELISA Kit, Cu[2+]/Zn[2+]SOD ELISA Kit, Dmel\\CG11793 ELISA Kit, G ELISA Kit, Mn SOD ELISA Kit, SOD-1 ELISA Kit, SOD1 ELISA Kit, Sod-1 ELISA Kit, Sod1 ELISA Kit, To ELISA Kit, To-1 ELISA Kit, Zn SOD ELISA Kit, Zn Sod ELISA Kit, Zn-SOD ELISA Kit, ZnSod ELISA Kit, cSOD ELISA Kit, cSod ELISA Kit, dSOD1 ELISA Kit, l(3)108 ELISA Kit, l(3)68Af' ELISA Kit, l(3)G ELISA Kit, sod ELISA Kit, sod1 ELISA Kit, CU/ZN-SOD ELISA Kit, SODC ELISA Kit, DKFZP469M1833 ELISA Kit, B430204E11Rik ELISA Kit, Cu/Zn-SOD ELISA Kit, Ipo-1 ELISA Kit, Ipo1 ELISA Kit, SOD1L1 ELISA Kit, XSODB ELISA Kit, als ELISA Kit, als1 ELISA Kit, ipoa ELISA Kit, sod1-a ELISA Kit, ZSOD ELISA Kit, cuzn ELISA Kit, Cu/Zn superoxide dismutase ELISA Kit, superoxide dismutase 1 ELISA Kit, Superoxide dismutase 1 ELISA Kit, superoxide dismutase 1, soluble ELISA Kit, superoxide dismutase 1 S homeolog ELISA Kit, Superoxide dismutase [Cu-Zn] ELISA Kit, superoxide dismutase 1 L homeolog ELISA Kit, superoxide dismutase [Cu-Zn]-like ELISA Kit, superoxide dismutase [Cu-Zn] ELISA Kit, superoxide dismutase Sod1 ELISA Kit, SOD ELISA Kit, SOD1 ELISA Kit, Sod1 ELISA Kit, sod1 ELISA Kit, sod1.S ELISA Kit, sod-1 ELISA Kit, sod1.L ELISA Kit, LOC101451855 ELISA Kit, LOC101115136 ELISA Kit
    Background
    SOD
    UniProt
    O73872
    Pathways
    Sensory Perception of Sound, Transition Metal Ion Homeostasis
Support