Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Reticulon 4 ELISA Kit

RTN4 Reactivity: Human Colorimetric Sandwich ELISA 78.13 pg/mL - 5000 pg/mL Cell Culture Supernatant, Plasma, Serum
Catalog No. ABIN6962625
  • Target See all Reticulon 4 (RTN4) ELISA Kits
    Reticulon 4 (RTN4)
    Reactivity
    • 3
    • 3
    • 1
    Human
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    78.13 pg/mL - 5000 pg/mL
    Minimum Detection Limit
    78.13 pg/mL
    Application
    ELISA
    Purpose
    The kit is a sandwich enzyme immunoassay technique for the in vitro quantitative measurement in various sample types.
    Sample Type
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Quantitative
    Specificity
    This kit recognizes Human RTN4 in samples. No Significant cross-reactivity or interference between Human RTN4 and analogues was observed.
    Sensitivity
    46.88 pg/mL
    Components
    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Reference Standard & Sample Diluent
    • Biotinylated Detection Antibody (100 x concentrate)
    • HRP Conjugate (100 x concentrate)
    • Biotinylated Detection Antibody Diluent
    • HRP Conjugate Diluent
    • Substrate Reagent
    • Stop Solution
    • Wash Buffer (25 x concentrate)
    • Instruction manual
    Featured
    Discover our best selling RTN4 ELISA Kit
    Top Product
    Discover our top product RTN4 ELISA Kit
  • Sample Volume
    100 μL
    Assay Time
    3.5 h
    Plate
    Pre-coated
    Protocol
    1. Add 100 µL standard or sample to each well. Incubate for 90 min at 37 °C.
    2. Remove the liquid. Add 100 µL Biotinylated Detection Antibody. Incubate for 1 hour at 37 °C.
    3. Aspirate and wash 3 times.
    4. Add 100 µL HRP Conjugate. Incubate for 30 min at 37 °C.
    5. Aspirate and wash 5 times.
    6. Add 90 µL Substrate Reagent. Incubate for 15 min at 37 °C.
    7. Add 50 µL Stop Solution. Read at 450 nm immediately.
    8. Calculation of results.
    Reagent Preparation
    1. Bring all reagents to room temperature (18~25 °C) before use. Follow the Microplate reader manual for set-up and preheat it for 15 min before OD measurement.
    2. Wash Buffer: Dilute 30 mL of Concentrated Wash Buffer with 720 mL of deionized or distilled water to prepare 750 mL of Wash Buffer.Note: if crystals have formed in the concentrate, warm it in a 40 °C water bath and mix it gently until the crystals have completely dissolved
    3. Standard working solution: Centrifuge the standard at 10,000xg for 1 min. Add 1.0 mL of Reference Standard &Sample Diluent, let it stand for 10 min and invert it gently several times. After it dissolves fully, mix it thoroughly with a pipette. This reconstitution produces a working solution of 5000 pg/mL. Then make serial dilutions as needed. The recommended dilution gradient is as follows: 5000, 2500, 1250, 625, 312.5, 156.25, 78.13, 0 pg/mL. Dilution method: Take 7 EP tubes, add 500 μLof Reference Standard & Sample Diluent to each tube. Pipette 500 μLof the 5000 pg/mL working solution to the first tube and mix up to produce a 2500 pg/mL working solution. Pipette 500 μLof the solution from the former tube into the latter one according to these steps. The illustration below is for reference. Note: the last tube is regarded as a blank. Don't pipette solution into it from the former tube.
    4. Biotinylated Detection Antibody working solution: Calculate the required amount before the experiment (100 μL/well). In preparation, slightly more than calculated should be prepared. Centrifuge the stock tube before use, dilute the 100x Concentrated Biotinylated Detection Antibody to 1xworking solution with Biotinylated Detection Antibody Diluent.
    5. Concentrated HRP Conjugate working solution: Calculate the required amount before the experiment (100 μL/well). In preparation, slightly more than calculated should be prepared. Dilute the 100x Concentrated HRP Conjugate to 1x working solution with Concentrated HRP Conjugate Diluent.
    Sample Preparation
    • It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturation may occur in these samples, leading to false results. Samples should therefore be stored for a short period at 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thaw cycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged to remove precipitates.
    • If the sample type is not specified in the instructions, a preliminary test is necessary to determine compatibility with the kit.
    • If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibility of causing a deviation due to the introduced chemical substance. The recommended dilution factor is for reference only.
    • Please estimate the concentration of the samples before performing the test. If the values are not in the range of the standard curve, the optimal sample dilution for the particular experiment has to be determined.
    Assay Precision
    Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Human RTN4 were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Human RTN4 were tested on 3 different plates, 20 replicates in each plate.
    Both intra-CV and inter-CV are < 10 %.
    Restrictions
    For Research Use only
  • Storage
    4 °C,-20 °C
    Storage Comment
    1. For unopened kit: All reagents should be stored according to the labels on the vials, so they are stable up to 12 months after receipt of the kit. The Reference Standard, Biotinylated Detection Antibody, HRP Conjugate and the 96-well stripe plate should be stored at -20 °C upon receipt while the other reagents should be stored at 4 °C.
    2. For used kit: When the kit is used, the remaining reagents need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and zip-seal the foil pouch.
    Expiry Date
    12 months
  • Target See all Reticulon 4 (RTN4) ELISA Kits
    Reticulon 4 (RTN4)
    Alternative Name
    Reticulon 4 (RTN4 Products)
    Synonyms
    ASY ELISA Kit, NI220/250 ELISA Kit, NOGO ELISA Kit, NOGO-A ELISA Kit, NOGOC ELISA Kit, NSP ELISA Kit, NSP-CL ELISA Kit, Nbla00271 ELISA Kit, Nbla10545 ELISA Kit, Nogo-B ELISA Kit, Nogo-C ELISA Kit, RTN-X ELISA Kit, RTN4-A ELISA Kit, RTN4-B1 ELISA Kit, RTN4-B2 ELISA Kit, RTN4-C ELISA Kit, RTN4-Cw ELISA Kit, DKFZp459C0314 ELISA Kit, 1110020G17Rik ELISA Kit, AA407876 ELISA Kit, AA409940 ELISA Kit, AA960376 ELISA Kit, C130026I10Rik ELISA Kit, NgA ELISA Kit, Nogo-A ELISA Kit, mKIAA0886 ELISA Kit, mKIAA4153 ELISA Kit, NI-250 ELISA Kit, Nogo ELISA Kit, Vp20 ELISA Kit, r ELISA Kit, rat N ELISA Kit, rat NogoA ELISA Kit, reticulon-4 ELISA Kit, nogo ELISA Kit, rtn4 ELISA Kit, wu:fb17a02 ELISA Kit, wu:fb22f12 ELISA Kit, wu:fd61a07 ELISA Kit, zgc:92163 ELISA Kit, reticulon 4 ELISA Kit, reticulon 4a ELISA Kit, RTN4 ELISA Kit, rtn4 ELISA Kit, Rtn4 ELISA Kit, rtn4a ELISA Kit
    Pathways
    Neurotrophin Signaling Pathway, Regulation of Cell Size, SARS-CoV-2 Protein Interactome
You are here: