BIRC2 IQ-ELISA Kit
-
- Target See all BIRC2 IQ-ELISA Kits
- BIRC2 (Baculoviral IAP Repeat Containing 2 (BIRC2))
-
Reactivity
- Human
- Detection Method
- qPCR
- Method Type
- DNA-Binding ELISA
- Detection Range
- 48 pg/mL - 200000 pg/mL
- Minimum Detection Limit
- 48 pg/mL
- Application
- ELISA
- Purpose
- Human Immunoquantitative (PCR-Based) cIAP-1 (BIRC2/hIAP-2) ELISA Kit for cell culture supernatants, plasma, and serum samples.
- Sample Type
- Cell Culture Supernatant, Plasma, Serum
- Analytical Method
- Quantitative
- Characteristics
- The Immuno Quantitative Enzyme Linked ImumunoSorbent Assay (IQELISA™) is an innovative new assay that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of lower sample volumes while also providing more sensitivity. The Human cIAP-1 (BIRC2/hIAP-2) IQELISA™ Kit is a modified ELISA assay with high sensitivity qPCR readout for the quantitative measurement of Human cIAP-1 (BIRC2/hIAP-2) in serum, plasma, and cell culture supernatants. This assay employs an antibody specific for Human cIAP-1 (BIRC2/hIAP-2) coated on a 96-well PCR plate. Standards and samples are pipetted into the wells and cIAP-1 (BIRC2/hIAP-2) present in a sample is bound to the wells by the immobilized antibody. The wells are washed and a detection affinity molecule is added to the plates. After washing away unbound detection affinity molecule, primers and a PCR master mix are added to the wells and data is collected using qPCR. Ct values obtained from the qPCR are then used to calculate the amount of antigen contained in each sample, where lower Ct values indicate a higher concentration of antigen.
- Components
-
- cIAP-1 (BIRC2/hIAP-2) Microplate (Item A): 96 well PCR plate coated with anti-Human cIAP-1 (BIRC2/hIAP-2)
- Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
- Standards (Item C): 2 vials of recombinant Human cIAP-1 (BIRC2/hIAP-2)
- Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
- Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
- Detection Affinity Reagent for cIAP-1 (BIRC2/hIAP-2) (Item F): 2 vials of a 4x concentrated solution of anti-Human cIAP-1 (BIRC2/hIAP-2) affinity reagent
- IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
- Primer Solution (Item I): 1.7 ml vial
- PCR Master Mix (Item J): 1.2 ml vial
- PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
- Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
- Material not included
-
- Real-time PCR instrument, Bio-Rad recommended
- Precision pipettes to deliver 2 μL to 1 mL volumes
- Adjustable 1-25 mL pipettes for reagent preparation
- 100 mL and 1 liter graduated cylinders
- Absorbent paper
- Distilled or deionized water
- Log-log graph paper or computer and software for data analysis
- Tubes to prepare standard or sample dilutions
- Heating block or water bath capable of 80°C
- Featured
- Discover our best selling BIRC2 ELISA Kit
- Top Product
- Discover our top product BIRC2 ELISA Kit
-
-
- Application Notes
- Optimal working dilution should be determined by the investigator.
- Comment
-
Features:
- Excellent for follow up/confirmation of antibody array data
- Pre-coated 96 well plate
- Strip plate format minimizes waste
- Complete kit includes all necessary reagents
- 10x more sensitive than ELISA
- Reproducible and reliable
- Optimized for serum, plasma, urine and cell culture medium
- 1/10th the sample volume of an ELISA
Research Applications:
- Detection of quantitative protein levels in biological fluids
- Validation of antibody array results
- Validation of biomarker discovery studies - Protocol
-
- Prepare all reagents, samples and standards as instructed
- Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
- Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
- Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
- Add 15μL Primer solution 10μL of PCR master mix to each well
- Run real-time PCR
- Reagent Preparation
-
Recommended Dilution for serum and plasma samples20 - 200 fold
- Restrictions
- For Research Use only
-
- Storage
- 4 °C,-20 °C,-80 °C
- Storage Comment
- May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
- Expiry Date
- 6 months
-
- Target See all BIRC2 IQ-ELISA Kits
- BIRC2 (Baculoviral IAP Repeat Containing 2 (BIRC2))
- Alternative Name
- cIAP-1 (BIRC2 Products)
- Synonyms
- API1 IQ-ELISA Kit, HIAP2 IQ-ELISA Kit, Hiap-2 IQ-ELISA Kit, MIHB IQ-ELISA Kit, RNF48 IQ-ELISA Kit, c-IAP1 IQ-ELISA Kit, cIAP1 IQ-ELISA Kit, Api2 IQ-ELISA Kit, rIAP1 IQ-ELISA Kit, IAP1 IQ-ELISA Kit, ITA IQ-ELISA Kit, AW146227 IQ-ELISA Kit, Api1 IQ-ELISA Kit, Birc3 IQ-ELISA Kit, HIAP1 IQ-ELISA Kit, IAP2 IQ-ELISA Kit, MIAP1 IQ-ELISA Kit, MIAP2 IQ-ELISA Kit, MIHC IQ-ELISA Kit, cIAP2 IQ-ELISA Kit, mcIAP1 IQ-ELISA Kit, ciap-1 IQ-ELISA Kit, birc3 IQ-ELISA Kit, api1 IQ-ELISA Kit, birc2 IQ-ELISA Kit, c-iap1 IQ-ELISA Kit, ciap1 IQ-ELISA Kit, hiap-2 IQ-ELISA Kit, hiap2 IQ-ELISA Kit, mihb IQ-ELISA Kit, rnf48 IQ-ELISA Kit, baculoviral IAP repeat containing 2 IQ-ELISA Kit, baculoviral IAP repeat-containing 2 IQ-ELISA Kit, baculoviral IAP repeat containing 2 L homeolog IQ-ELISA Kit, BIRC2 IQ-ELISA Kit, Birc2 IQ-ELISA Kit, birc2 IQ-ELISA Kit, birc2.L IQ-ELISA Kit
- Gene ID
- 329
- UniProt
- Q13490
- Pathways
- Apoptosis, Caspase Cascade in Apoptosis, Activation of Innate immune Response, Toll-Like Receptors Cascades
-