Aminoacylase 1 ELISA Kit
-
- Target See all Aminoacylase 1 (ACY1) ELISA Kits
- Aminoacylase 1 (ACY1)
-
Reactivity
- Mouse
- Detection Method
- Colorimetric
- Method Type
- Sandwich ELISA
- Application
- ELISA
- Purpose
- Mouse Aminoacylase/ACY1 ELISA Kit.
- Sample Type
- Cell Culture Supernatant, Cell Samples, Plasma, Serum, Tissue Lysate
- Analytical Method
- Quantitative
- Specificity
- This ELISA antibody pair recognizes Mouse Aminoacylase.
- Characteristics
-
- Strip plates and additional reagents allow for use in multiple experiments
- Quantitative protein detection
- Establishes normal range
- The best products for confirmation of antibody array data
- Components
-
- Pre-Coated 96-well Strip Microplate
- Wash Buffer
- Stop Solution
- Assay Diluent(s)
- Lyophilized Standard
- Biotinylated Detection Antibody
- Streptavidin-Conjugated HRP
- TMB One-Step Substrate
- Material not included
-
- Distilled or deionized water
- Precision pipettes to deliver 2 µl to 1 µl volumes
- Adjustable 1-25 µl pipettes for reagent preparation
- 100 µl and 1 liter graduated cylinders
- Tubes to prepare standard and sample dilutions
- Absorbent paper
- Microplate reader capable of measuring absorbance at 450nm
- Log-log graph paper or computer and software for ELISA data analysis
- Top Product
- Discover our top product ACY1 ELISA Kit
-
-
- Application Notes
- Optimal working dilution should be determined by the investigator.
- Protocol
-
- Prepare all reagents, samples and standards as instructed in the manual.
- Add 100 µl of standard or sample to each well.
- Incubate 2.5 h at RT or O/N at 4°C.
- Add 100 µl of prepared biotin antibody to each well.
- Incubate 1 h at RT.
- Add 100 µl of prepared Streptavidin solution to each well.
- Incubate 45 min at RT.
- Add 100 µl of TMB One-Step Substrate Reagent to each well.
- Incubate 30 min at RT.
- Add 50 µl of Stop Solution to each well.
- Read at 450 nm immediately.
- Restrictions
- For Research Use only
-
- Storage Comment
- The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
- Expiry Date
- 6 months
-
- Target See all Aminoacylase 1 (ACY1) ELISA Kits
- Aminoacylase 1 (ACY1)
- Alternative Name
- Aminoacylase (ACY1 (ACY1 Products)
- Synonyms
- si:zfos-226g1.1 ELISA Kit, zgc:55605 ELISA Kit, zgc:76955 ELISA Kit, acy1 ELISA Kit, acy1d ELISA Kit, acylase ELISA Kit, ACY1 ELISA Kit, ACY-1 ELISA Kit, ACY1D ELISA Kit, 1110014J22Rik ELISA Kit, Acy-1 ELISA Kit, Acy1a ELISA Kit, Acy1b ELISA Kit, aminoacylase 1 ELISA Kit, aminoacylase 1, gene 1 S homeolog ELISA Kit, aminoacylase 1, gene 1 ELISA Kit, ACY1 ELISA Kit, acy1 ELISA Kit, acy1.1.S ELISA Kit, acy1.1 ELISA Kit, Acy1 ELISA Kit
- UniProt
- Q99JW2
-