Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

OPCML IQ-ELISA Kit

OPCML Reactivity: Human qPCR Sandwich ELISA Cell Culture Supernatant, Plasma, Serum
Catalog No. ABIN6386192
  • Target See all OPCML products
    OPCML (Opioid Binding Protein/cell Adhesion Molecule-Like (OPCML))
    Reactivity
    Human
    Detection Method
    qPCR
    Method Type
    Sandwich ELISA
    Application
    ELISA
    Purpose
    Human Immunoquantitative (PCR-Based) OBCAM ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Sample Type
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Semi-Quantitative
    Characteristics
    IQ-ELISAs employ specific capture antibodies coated on a 96-well PCR plate. Standards and samples are pipetted into the wells, the target protein in the standards and samples binds to the immobilized antibody. The wells are washed and the detection affinity reagent is added to the wells where it binds to any captured antigen. The wells are washed, and primers and PCR master mix are added to each well. The plate is placed into a real time PCR instrument for cycling and measurement of DNA amplification. The cycle number where amplification is detected is proportional to the amount of affinity detection reagent that bound to captured antigen in each well.
    Components
    • OBCAM Microplate (Item A): 96 well PCR plate coated with anti-Human OBCAM
    • Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
    • Standards (Item C): 2 vials of recombinant Human OBCAM
    • Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
    • Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
    • Detection Affinity Reagent for OBCAM (Item F): 2 vials of a 4x concentrated solution of anti-Human OBCAM affinity reagent
    • IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
    • Primer Solution (Item I): 1.7 ml vial
    • PCR Master Mix (Item J): 1.2 ml vial
    • PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
    • Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
    Material not included
    • Real-time PCR instrument, Bio-Rad recommended
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Absorbent paper
    • Distilled or deionized water
    • Log-log graph paper or computer and software for data analysis
    • Tubes to prepare standard or sample dilutions
    • Heating block or water bath capable of 80°C
  • Application Notes
    The Immuno-Quantitative ELISA (IQELISA) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of only 1/10th the sample volume while also providing 10x more sensitivity than a traditional ELISA.
    Comment

    The Immuno-Quantitative ELISA (IQELISA™) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. Also called immuno-PCR, this detection platform results in an assay that is simultaneously familiar and cutting edge. Compared to traditional ELISA, IQELISA™ enables the use of only 1/10th the sample volume while also providing 10x more sensitivity.

    Sample Volume
    25 µL
    Plate
    Pre-coated
    Protocol
    1. Prepare all reagents, samples and standards as instructed
    2. Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
    3. Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
    4. Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
    5. Add 15μL Primer solution 10μL of PCR master mix to each well
    6. Run real-time PCR
    Restrictions
    For Research Use only
  • Storage
    4 °C,-20 °C,-80 °C
    Storage Comment
    May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
    Expiry Date
    6 months
  • Target See all OPCML products
    OPCML (Opioid Binding Protein/cell Adhesion Molecule-Like (OPCML))
    Alternative Name
    OBCAM (OPCML Products)
    Synonyms
    IGLON1 IQ-ELISA Kit, OBCAM IQ-ELISA Kit, OPCM IQ-ELISA Kit, 2900075O15Rik IQ-ELISA Kit, 3732419F12 IQ-ELISA Kit, AI844366 IQ-ELISA Kit, B930023M13Rik IQ-ELISA Kit, C230027C17 IQ-ELISA Kit, Gm181 IQ-ELISA Kit, Obcam IQ-ELISA Kit, opioid binding protein/cell adhesion molecule like IQ-ELISA Kit, opioid binding protein/cell adhesion molecule-like IQ-ELISA Kit, OPCML IQ-ELISA Kit, Opcml IQ-ELISA Kit
    Gene ID
    4978
    UniProt
    Q14982
You are here:
Support