Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

CD2 IQ-ELISA Kit

CD2 Reactivity: Human qPCR Sandwich ELISA Cell Culture Supernatant, Plasma, Serum
Catalog No. ABIN6384340
  • Target See all CD2 IQ-ELISA Kits
    CD2
    Reactivity
    • 2
    • 1
    • 1
    • 1
    Human
    Detection Method
    qPCR
    Method Type
    Sandwich ELISA
    Application
    ELISA
    Purpose
    Human Immunoquantitative (PCR-Based) CD2 ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Sample Type
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Semi-Quantitative
    Characteristics
    IQ-ELISAs employ specific capture antibodies coated on a 96-well PCR plate. Standards and samples are pipetted into the wells, the target protein in the standards and samples binds to the immobilized antibody. The wells are washed and the detection affinity reagent is added to the wells where it binds to any captured antigen. The wells are washed, and primers and PCR master mix are added to each well. The plate is placed into a real time PCR instrument for cycling and measurement of DNA amplification. The cycle number where amplification is detected is proportional to the amount of affinity detection reagent that bound to captured antigen in each well.
    Components
    • CD2 Microplate (Item A): 96 well PCR plate coated with anti-Human CD2
    • Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
    • Standards (Item C): 2 vials of recombinant Human CD2
    • Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
    • Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
    • Detection Affinity Reagent for CD2 (Item F): 2 vials of a 4x concentrated solution of anti-Human CD2 affinity reagent
    • IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
    • Primer Solution (Item I): 1.7 ml vial
    • PCR Master Mix (Item J): 1.2 ml vial
    • PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
    • Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
    Material not included
    • Real-time PCR instrument, Bio-Rad recommended
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Absorbent paper
    • Distilled or deionized water
    • Log-log graph paper or computer and software for data analysis
    • Tubes to prepare standard or sample dilutions
    • Heating block or water bath capable of 80°C
    Featured
    Discover our best selling CD2 ELISA Kit
    Top Product
    Discover our top product CD2 ELISA Kit
  • Application Notes
    The Immuno-Quantitative ELISA (IQELISA) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of only 1/10th the sample volume while also providing 10x more sensitivity than a traditional ELISA.
    Comment

    The Immuno-Quantitative ELISA (IQELISA™) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. Also called immuno-PCR, this detection platform results in an assay that is simultaneously familiar and cutting edge. Compared to traditional ELISA, IQELISA™ enables the use of only 1/10th the sample volume while also providing 10x more sensitivity.

    Sample Volume
    25 µL
    Plate
    Pre-coated
    Protocol
    1. Prepare all reagents, samples and standards as instructed
    2. Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
    3. Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
    4. Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
    5. Add 15μL Primer solution 10μL of PCR master mix to each well
    6. Run real-time PCR
    Restrictions
    For Research Use only
  • Storage
    4 °C,-20 °C,-80 °C
    Storage Comment
    May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
    Expiry Date
    6 months
  • Target See all CD2 IQ-ELISA Kits
    CD2
    Alternative Name
    CD2 (CD2 Products)
    Synonyms
    CD2 IQ-ELISA Kit, LFA-2 IQ-ELISA Kit, Ly-37 IQ-ELISA Kit, Ly37 IQ-ELISA Kit, SRBC IQ-ELISA Kit, T11 IQ-ELISA Kit, CD2R IQ-ELISA Kit, LFA2 IQ-ELISA Kit, OX-34 IQ-ELISA Kit, OX34 IQ-ELISA Kit, CD2 molecule IQ-ELISA Kit, CD2 antigen IQ-ELISA Kit, Cd2 molecule IQ-ELISA Kit, CD2 IQ-ELISA Kit, Cd2 IQ-ELISA Kit
    Gene ID
    914
    UniProt
    P06729
You are here:
Support