Urinary Creatinine Detection Kit

BCA Reactivity: Dog, Monkey Colorimetric Urine
Catalog No. ABIN577638
  • Target See all Creatinine (CR) products
    Creatinine (CR)
    Reactivity
    • 3
    • 3
    • 3
    • 3
    • 3
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Dog, Monkey
    Detection Method
    Colorimetric
    Minimum Detection Limit
    0.037 mg/dL
    Application
    Biochemical Assay (BCA)
    Purpose
    The DetectX® Urinary Creatinine kit is designed to quantitatively measure creatinine present inurine samples.
    Brand
    DetectX®
    Sample Type
    Urine
    Specificity
    Species Independent. Validated samples: Human, Monkey, Dog, and Rat Urine.
    This assay has been validated for human, rat, dog and monkey urine samples. Urine samples containing visible protein or particulates should be centrifuged or filtered prior to using. Mouse urine samples are not compatible with the use of this assay to determine GFR as over half of murine urinary creatinine is from renal secretion rather than filtration
    Sensitivity
    0.19 µg/mL
    Characteristics
    The Creatinine kits are designed to quantitatively measure creatinine in urine samples. A NIST calibrated creatinine standard is used to standardize the assay. Samples are pipetted into a clear microtiter plate and the color generating reaction is initiated with the supplied no-mix DetectX Creatinine Reagent, which is pipetted into each well. After a 30 minute incubation at room temperature the color is read at 490nm. Creatinine (2-amino-1-methyl-5H-imadazol-4-one) is a metabolite of phosphocreatine (p-creatine), a molecule used as a store for high-energy phosphate that can be utilized by tissues for the production of ATP. Creatine either comes from the diet or synthesized from the amino acids arginine, glycine, and methionine. Creatine and p-creatine are converted non-enzymatically to the metabolite creatinine, which diffuses into the blood and is excreted by the kidneys. In vivo, this conversion appears to be irreversible and in vitro it is favored by higher temperatures and lower pH. Creatinine forms spontaneously from p-creatine. Under normal conditions, its formation occurs at a rate that is relatively constant and as intra-individual variation is <15% from day to day, creatinine is a useful tool for normalizing the levels of other molecules found in urine.
    Components
    Clear Microtiter Plates Bag containing 2 by 96 well plates or 2 bags each containing 5 by 96 well plates 2 plates 2 or 5 plates
    Creatinine standard A 100 mg/dL creatinine solution in deionized water. 1 mL or 1 mL Calibrated to NIST Standard Reference Material Lot Number 914a
    DetectX® Creatinine reagent 20 mL or 50 mL
    Plate sealers 2 or 10 each
    Material not included
    Distilled or deionized water.
    Colorimetric 96 well microplate reader capable of reading optical density at 490 nm, preferably with correction between 570 and 590 nm.
    Software for converting raw relative optical density readings from the plate reader and carrying out four parameter logistic curve (4PLC) fitting.
  • Application Notes
    This assay has been validated for human, rat, dog and monkey urine samples.
    Urine samples containing visible protein or particulates should be centrifuged or filtered prior to using.
    Mouse urine samples are not compatible with the use of this assay to determine GFR as over half of murine urinary creatinine is from renal secretion rather than filtration9.
    For measuring Creatinine in serum or plasma samples please refer to the DetectX® Serum Creatinine Detection kit,
    Comment

    Sample values: 47 random clean catch human urine samples were tested in the assay.
    Neat urine values ranged from 17.2 to 168.9 mg/dL with an average of 90.7 mg/dL.
    One sample each of beagle and rat urines diluted 1:20 with water and read in the kit gave creatinine values in neat urine of 92.8 and 25.2 mg/dL respectively.
    A single Rhesus monkey urine, diluted either 1:2 or 1:5, averaged 2.65 mg/dL in neat urine.

    Protocol
    A creatinine standard, calibrated to a NIST creatinine standard, is provided to generate a standard curve for the assay and all samples should be read off the standard curve.
    Standards or diluted samples are pipetted into a clear microtiter plate.
    The color generating reaction is initiated with the DetectX® Creatinine Reagent, which is pipetted into each well.
    After a short incubation the intensity of the generated color is detected in a microtiter plate reader capable of measuring 490nm wavelength.
    The concentration of the creatine in the sample is calculated, after making a suitable correction for the dilution of the sample, using software available with most plate readers.
    The Jaffe reaction used in this kit has been modified to read creatinine levels in urine
    Reagent Preparation

    Allow the kit reagents to come to room temperature for 30 minutes.
    Ensure that all samples have reached room temperature and have been diluted as appropriate prior to running them in the kit. standard Preparation Label seven glass test tubes #1 through #7.
    Pipet 800 μL of water into tube #1 and 500 μL into tubes #2-#7.
    Carefully add 200 μL of the Creatinine Standard stock solution to tube #1 and vortex completely.
    Take 500 μL of the creatinine solution in tube #1 and add it to tube #2 and vortex completely.
    Add 500 μL of tube #2 to tube #3 and vortex completely.
    Repeat these serial dilutions for tubes #4 through #7.
    The concentration of creatinine in tubes 1 through 7 will be 20, 10, 5, 2.5, 1.25, 0.625 and 0.3125 mg/dL.
    Water will be used as a sample blank.
    Use all standards within 2 hours of preparation.

    Sample Preparation

    Rhesus monkey urine samples contain very low levels of creatinine and should be diluted 1:2 in water by taking one part of urine and adding to one part of water prior to using in the assay. All other urine samples must be diluted 1:20 with deionized or distilled water by taking one part of urine and adding to nineteen parts of water to obtain accurate results. Any urine samples with creatinine concentrations outside the standard curve range should be diluted further with water to obtain readings within the standard curve. Use all diluted samples within 2 hours of preparation.

    Assay Procedure

    We recommend that all standards and samples be run in duplicate to allow the end user to accurately determine creatinine concentrations.
    1. Use the plate layout sheet on the back page to aid in proper sample and standard identification.
    2. Pipet 50 μL of samples, water as the blank, or standards into wells in the clear plate.
    3. Add 100 μL of the DetectX® Creatinine Reagent to each well using a repeater pipet.
    4. Gently tap the sides of the plate to ensure adequate mixing of the reagents. Cover the plate with the plate sealer and press to seal adequately.
    5. Incubate at room temperature for 30 minutes.
    6. Read the optical density generated from each well in a plate reader capable of reading at 490nm.
    7. Use the plate reader's built-in 4PLC software capabilities to calculate creatinine concentrations for each sample.

    Calculation of Results

    Average the duplicate OD readings for each standard and sample.
    Create a standard curve by reducing the data using computer software capable of generating a four-parameter logistic curve (4PLC) fit, after subtracting the mean OD's for the blank.
    The sample concentrations obtained should be multiplied by the dilution factor to obtain neat sample values.

    Restrictions
    For Research Use only
  • Precaution of Use
    As with all such products, this kit should only be used by qualified personnel who have had laboratory safety instruction.
    The complete insert should be read and understood before attempting to use the product.
    The Creatinine Reagent contains hazardous chemicals.
    It contains a solution of basic picric acid in a stabilizing solution.
    The solution should not come in contact with skin or eyes.
    Picric acid is an irritant and, if dried, potentially explosive.
    Avoid contact with metals and use large volumes of water during disposal.
    Take appropriate precautions when handling these reagents.
    Storage
    4 °C
    Storage Comment
    All components of this kit should be stored at 4°C until the expiration date of the kit.
  • Hansen, Roager, Søndertoft, Gøbel, Kristensen, Vallès-Colomer, Vieira-Silva, Ibrügger, Lind, Mærkedahl, Bahl, Madsen, Havelund, Falony, Tetens, Nielsen, Allin, Frandsen, Hartmann, Holst, Sparholt et al.: "A low-gluten diet induces changes in the intestinal microbiome of healthy Danish adults. ..." in: Nature communications, Vol. 9, Issue 1, pp. 4630, (2019) (PubMed).

    Bortey-Sam, Ikenaka, Akoto, Nakayama, Asante, Baidoo, Obirikorang, Mizukawa, Ishizuka: "Association between human exposure to heavy metals/metalloid and occurrences of respiratory diseases, lipid peroxidation and DNA damage in Kumasi, Ghana." in: Environmental pollution (Barking, Essex : 1987), Vol. 235, pp. 163-170, (2018) (PubMed).

    Ponnusamy, Sinha, Hyde, Borland, Taylor, Pond, Eyre, Inkson, Gilmore, Ashton, Kalra, Canfield: "FTI-277 inhibits smooth muscle cell calcification by up-regulating PI3K/Akt signaling and inhibiting apoptosis." in: PLoS ONE, Vol. 13, Issue 4, pp. e0196232, (2018) (PubMed).

    Rist, Roth, Frommherz, Weinert, Krüger, Merz, Bunzel, Mack, Egert, Bub, Görling, Tzvetkova, Luy, Hoffmann, Kulling, Watzl: "Metabolite patterns predicting sex and age in participants of the Karlsruhe Metabolomics and Nutrition (KarMeN) study." in: PLoS ONE, Vol. 12, Issue 8, pp. e0183228, (2017) (PubMed).

    Klocke, Kopetschke, Grießbach, Langhans, Humrich, Biesen, Dragun, Radbruch, Burmester, Riemekasten, Enghard: "Mapping urinary chemokines in human lupus nephritis: Potentially redundant pathways recruit CD4(+) and CD8(+) T cells and macrophages." in: European journal of immunology, (2016) (PubMed).

    Pignatelli, Pastori, Bartimoccia, Menichelli, Vicario, Nocella, Carnevale, Violi: "Anti Xa oral anticoagulants inhibit in vivo platelet activation by modulating glycoprotein VI shedding." in: Pharmacological research, Vol. 113, Issue Pt A, pp. 484-489, (2016) (PubMed).

    Brand, Boose, Squires, Marchant, White, Meinelt, Snodgrass: "Hair plucking, stress, and urinary cortisol among captive bonobos (Pan paniscus)." in: Zoo biology, Vol. 35, Issue 5, pp. 415-422, (2016) (PubMed).

    Jang, Park, Kwon, Park, Lee, Kim, Kim, Kim, Oh, Huh: "Aging has small effects on initial ischemic acute kidney injury development despite changing intrarenal immunologic micromilieu in mice." in: American journal of physiology. Renal physiology, Vol. 310, Issue 4, pp. F272-83, (2016) (PubMed).

    Eirin, Saad, Tang, Herrmann, Woollard, Lerman, Textor, Lerman: "Urinary Mitochondrial DNA Copy Number Identifies Chronic Renal Injury in Hypertensive Patients." in: Hypertension (Dallas, Tex. : 1979), Vol. 68, Issue 2, pp. 401-10, (2016) (PubMed).

    Leibrock, Voelkl, Kohlhofer, Quintanilla-Martinez, Kuro-O, Lang: "Bicarbonate-sensitive calcification and lifespan of klotho-deficient mice." in: American journal of physiology. Renal physiology, Vol. 310, Issue 1, pp. F102-8, (2015) (PubMed).

    Weinert, Egert, Kulling: "On the applicability of comprehensive two-dimensional gas chromatography combined with a fast-scanning quadrupole mass spectrometer for untargeted large-scale metabolomics." in: Journal of chromatography. A, Vol. 1405, pp. 156-67, (2015) (PubMed).

    Jonscher, Osypuk, van Bokhoven, Lucia: "Evaluation of urinary protein precipitation protocols for the multidisciplinary approach to the study of chronic pelvic pain research network." in: Journal of biomolecular techniques : JBT, Vol. 25, Issue 4, pp. 118-26, (2015) (PubMed).

    Galarreta, Forbes, Thornhill, Antignac, Gubler, Nevo, Murphy, Chevalier: "The swan-neck lesion: proximal tubular adaptation to oxidative stress in nephropathic cystinosis." in: American journal of physiology. Renal physiology, Vol. 308, Issue 10, pp. F1155-66, (2015) (PubMed).

    Latchoumycandane, Nagy, McIntyre: "Myeloperoxidase formation of PAF receptor ligands induces PAF receptor-dependent kidney injury during ethanol consumption." in: Free radical biology & medicine, Vol. 86, pp. 179-90, (2015) (PubMed).

    Wang, Gu, Loyd, Jia, Groome: "Increased urinary levels of podocyte glycoproteins, matrix metallopeptidases, inflammatory cytokines, and kidney injury biomarkers in women with preeclampsia." in: American journal of physiology. Renal physiology, Vol. 309, Issue 12, pp. F1009-17, (2015) (PubMed).

    Bábíčková, Borbélyová, Tóthová, Kubišová, Janega, Hodosy, Celec: "The renal effects of prenatal testosterone in rats." in: The Journal of urology, Vol. 193, Issue 5, pp. 1700-8, (2015) (PubMed).

    Cantaluppi, Medica, Mannari, Stiaccini, Figliolini, Dellepiane, Quercia, Migliori, Panichi, Giovannini, Bruno, Tetta, Biancone, Camussi: "Endothelial progenitor cell-derived extracellular vesicles protect from complement-mediated mesangial injury in experimental anti-Thy1.1 glomerulonephritis." in: Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association, Vol. 30, Issue 3, pp. 410-22, (2015) (PubMed).

    Bracci, Manzella, Copertaro, Staffolani, Strafella, Barbaresi, Copertaro, Rapisarda, Valentino, Santarelli: "Rotating-shift nurses after a day off: peripheral clock gene expression, urinary melatonin, and serum 17-β-estradiol levels." in: Scandinavian journal of work, environment & health, Vol. 40, Issue 3, pp. 295-304, (2014) (PubMed).

    Webb-Robertson, Kim, Zink, Hallaian, Zhang, Madupu, Waters, Metz: "A Statistical Analysis of the Effects of Urease Pre-treatment on the Measurement of the Urinary Metabolome by Gas Chromatography-Mass Spectrometry." in: Metabolomics : Official journal of the Metabolomic Society, Vol. 10, Issue 5, pp. 897-908, (2014) (PubMed).

    Martinez, Sinedino, Bisinotto, Ribeiro, Gomes, Lima, Greco, Risco, Galvão, Taylor-Rodriguez, Driver, Thatcher, Santos: "Effect of induced subclinical hypocalcemia on physiological responses and neutrophil function in dairy cows." in: Journal of dairy science, Vol. 97, Issue 2, pp. 874-87, (2014) (PubMed).

  • Target
    Creatinine (CR)
    Alternative Name
    Creatinine (CR Products)
    Target Type
    Amino Acid
    Background
    Creatinine (2-amino-1-methyl-5H-imadazol-4-one) is a metabolite of phosphocreatine (p-creatine), a molecule used as a store for high-energy phosphate that can be utilized by tissues for the production of ATP1. Creatine either comes from the diet or synthesized from the amino acids arginine, glycine, and methionine. This occurs in the kidneys and liver, although other organ systems may be involved and species-specific differences may exist2. Creatine and p-creatine are converted non-enzymatically to the metabolite creatinine, which diffuses into the blood and is excreted by the kidneys. In vivo, this conversion appears to be irreversible and in vitro it is favored by higher temperatures and lower pH 2. Creatinine forms spontaneously from p-creatine3. Under normal conditions, its formation occurs at a rate that is relatively constant and as intra-individual variation is <15 % from day to day, creatinine is a useful tool for normalizing the levels of other molecules found in urine. Additionally altered creatinine levels may be associated with other conditions that result in decreased renal blood flow such as diabetes and cardiovascular disease4-6. 2- Po3 AtP ADP nH nH2 HooC HooC nH nH Creatine Kinase n n Creatine H Phosphocreatine o n nH n Creatinine
You are here:
Support