Relaxin 3 ELISA Kit
-
- Target See all Relaxin 3 (RLN3) ELISA Kits
- Relaxin 3 (RLN3)
-
Reactivity
- Rat
- Detection Method
- Colorimetric
- Method Type
- Competition ELISA
- Detection Range
- 123.46 pg/mL - 10000 pg/mL
- Minimum Detection Limit
- 123.46 pg/mL
- Application
- ELISA
- Sample Type
- Plasma, Serum
- Analytical Method
- Quantitative
- Specificity
- This assay has high sensitivity and excellent specificity for detection of Relaxin 3 (RLN3). No significant cross-reactivity or interference between Relaxin 3 (RLN3) and analogues was observed.
- Sensitivity
- 43.6 pg/mL
- Featured
- Discover our best selling RLN3 ELISA Kit
- Top Product
- Discover our top product RLN3 ELISA Kit
-
-
- Comment
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Assay Time
- 2 h
- Plate
- Pre-coated
- Protocol
- This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Relaxin 3 (RLN3) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Relaxin 3 (RLN3) and unlabeled Relaxin 3 (RLN3) (Standards or samples) with the pre-coated antibody specific to Relaxin 3 (RLN3). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Relaxin 3 (RLN3) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Relaxin 3 (RLN3) in the sample.
- Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Relaxin 3 (RLN3) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Relaxin 3 (RLN3) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Handling Advice
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Storage
- 4 °C,-20 °C
- Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Expiry Date
- 4-8 months
-
- Target See all Relaxin 3 (RLN3) ELISA Kits
- Relaxin 3 (RLN3)
- Alternative Name
- Relaxin 3 (RLN3 Products)
- Synonyms
- RFLB ELISA Kit, RLX3 ELISA Kit, RFLC2 ELISA Kit, rln3 ELISA Kit, rlx 3a ELISA Kit, rlx3a ELISA Kit, rxn3 ELISA Kit, RFLCI ELISA Kit, insl7 ELISA Kit, zins4 ELISA Kit, H3 ELISA Kit, RXN3 ELISA Kit, ZINS4 ELISA Kit, M3 ELISA Kit, Insl7 ELISA Kit, Relaxin-3 ELISA Kit, relaxin 3 ELISA Kit, relaxin 3a ELISA Kit, RLN3 ELISA Kit, rln3a ELISA Kit, rln3 ELISA Kit, Rln3 ELISA Kit
- Background
-
Gene Name: Relaxin 3
Gene Aliases: ZINS4, RXN3, H3, INSL7, Insulin-like peptide 7, Prorelaxin H3
- Gene ID
- 266997
- UniProt
- Q8BFS3
- Pathways
- Hormone Activity, cAMP Metabolic Process
-