NOX1 CLIA Kit
-
- Target See all NOX1 CLIA Kits
- NOX1 (NADPH Oxidase 1 (NOX1))
-
Reactivity
- Rat
- Detection Method
- Chemiluminescent
- Method Type
- Sandwich ELISA
- Detection Range
- 312.5 pg/mL - 20000 pg/mL
- Minimum Detection Limit
- 312.5 pg/mL
- Application
- ELISA
- Sample Type
- Tissue Homogenate
- Analytical Method
- Quantitative
- Specificity
- This assay has high sensitivity and excellent specificity for detection of Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1). No significant cross-reactivity or interference between Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) and analogues was observed.
- Sensitivity
- 11.88 pg/mL
- Featured
- Discover our best selling NOX1 ELISA Kit
- Top Product
- Discover our top product NOX1 ELISA Kit
-
-
- Comment
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Assay Time
- 2 - 3 h
- Plate
- Pre-coated
- Protocol
- The microplate provided in this kit has been pre-coated with an antibody specific to Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) level in the sample or standard.,
- Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Handling Advice
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Storage
- 4 °C,-20 °C
- Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Expiry Date
- 4-8 months
-
- Target See all NOX1 CLIA Kits
- NOX1 (NADPH Oxidase 1 (NOX1))
- Alternative Name
- Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1 (NOX1 Products)
- Synonyms
- GP91-2 CLIA Kit, MOX1 CLIA Kit, NOH-1 CLIA Kit, NOH1 CLIA Kit, NOX1a CLIA Kit, NOX1alpha CLIA Kit, Nox-1 CLIA Kit, Nox1 CLIA Kit, NADPH oxidase 1 CLIA Kit, NOX1 CLIA Kit, Nox1 CLIA Kit, nox1 CLIA Kit
- Background
-
Gene Name: Nicotinamide Adenine Dinucleotide Phosphate Oxidase 1
Gene Aliases: MOX1, GP91-2, NOH1, NADPH Oxidase 1, Mitogenic Oxidase(Pyridine Nucleotide-Dependent Superoxide-Generating, NADH/NADPH mitogenic oxidase subunit P65-MOX
- Gene ID
- 114243
- UniProt
- Q9WV87
- Pathways
- Regulation of Systemic Arterial Blood Pressure by Hormones, Proton Transport
-