MX2 ELISA Kit
-
- Target See all MX2 ELISA Kits
- MX2 (MX dynamin like GTPase 2 (MX2))
- Reactivity
- Human
- Detection Method
- Colorimetric
- Method Type
- Sandwich ELISA
- Detection Range
- 0.156 ng/mL - 10 ng/mL
- Minimum Detection Limit
- 0.156 ng/mL
- Application
- ELISA
- Sample Type
- Plasma, Serum, Tissue Homogenate
- Analytical Method
- Quantitative
- Specificity
- This assay has high sensitivity and excellent specificity for detection of Myxovirus Resistance 2 (MX2). No significant cross-reactivity or interference between Myxovirus Resistance 2 (MX2) and analogues was observed.
- Sensitivity
- 0.055 ng/mL
- Featured
- Discover our best selling MX2 ELISA Kit
- Top Product
- Discover our top product MX2 ELISA Kit
-
-
- Comment
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Assay Time
- 3 h
- Plate
- Pre-coated
- Protocol
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Myxovirus Resistance 2 (MX2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Myxovirus Resistance 2 (MX2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Myxovirus Resistance 2 (MX2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Myxovirus Resistance 2 (MX2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myxovirus Resistance 2 (MX2) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myxovirus Resistance 2 (MX2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Handling Advice
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Storage
- 4 °C,-20 °C
- Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Expiry Date
- 4-8 months
-
- Target See all MX2 ELISA Kits
- MX2 (MX dynamin like GTPase 2 (MX2))
- Alternative Name
- Myxovirus Resistance 2 (MX2 Products)
- Synonyms
- AI528743 ELISA Kit, Mx-2 ELISA Kit, Mx3 ELISA Kit, MXB ELISA Kit, MX dynamin-like GTPase 2 ELISA Kit, MX dynamin like GTPase 2 ELISA Kit, myxovirus (influenza virus) resistance 2 (mouse) ELISA Kit, Mx2 ELISA Kit, MX2 ELISA Kit
- Background
-
Gene Name: Myxovirus Resistance 2
Gene Aliases: MXB, Interferon-Regulated Resistance GTP-Binding Protein MXB, Second Interferon-Induced Protein p78
- Gene ID
- 4600
- UniProt
- P20592
-