Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

MYOC ELISA Kit

MYOC Reactivity: Human Colorimetric Sandwich ELISA 0.781 ng/mL - 50 ng/mL Tissue Homogenate
Catalog No. ABIN5657067
  • Target See all MYOC ELISA Kits
    MYOC (Myocilin (MYOC))
    Reactivity
    Human
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    0.781 ng/mL - 50 ng/mL
    Minimum Detection Limit
    0.781 ng/mL
    Application
    ELISA
    Sample Type
    Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of Myocilin (MYOC). No significant cross-reactivity or interference between Myocilin (MYOC) and analogues was observed.
    Sensitivity
    0.26 ng/mL
    Featured
    Discover our best selling MYOC ELISA Kit
    Top Product
    Discover our top product MYOC ELISA Kit
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time
    3 h
    Plate
    Pre-coated
    Protocol
    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Myocilin (MYOC). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Myocilin (MYOC). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Myocilin (MYOC), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Myocilin (MYOC) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
    Assay Precision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myocilin (MYOC) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myocilin (MYOC) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Restrictions
    For Research Use only
  • Handling Advice
    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Storage
    4 °C,-20 °C
    Storage Comment
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Expiry Date
    4-8 months
  • Target See all MYOC ELISA Kits
    MYOC (Myocilin (MYOC))
    Alternative Name
    Myocilin (MYOC Products)
    Synonyms
    MYOC ELISA Kit, MGC136645 ELISA Kit, zgc:136645 ELISA Kit, AI957332 ELISA Kit, GLC1A ELISA Kit, TIGR ELISA Kit, GPOA ELISA Kit, JOAG ELISA Kit, JOAG1 ELISA Kit, myocilin ELISA Kit, Tigr ELISA Kit, myocilin ELISA Kit, MYOC ELISA Kit, myoc ELISA Kit, Myoc ELISA Kit
    Background

    Gene Name: Myocilin

    Gene Aliases: GLC1A, GPOA, JOAG, JOAG1, TIGR, Trabecular Meshwork Inducible Glucocorticoid Response, Myocilin 55 kDa subunit

    Gene ID
    4653
    UniProt
    Q99972
You are here:
Support