MCM3 ELISA Kit
-
- Target See all MCM3 ELISA Kits
- MCM3 (Minichromosome Maintenance Complex Component 3 (MCM3))
- Reactivity
- Human
- Detection Method
- Colorimetric
- Method Type
- Sandwich ELISA
- Detection Range
- 0.156 ng/mL - 10 ng/mL
- Minimum Detection Limit
- 0.156 ng/mL
- Application
- ELISA
- Sample Type
- Cell Lysate, Tissue Homogenate
- Analytical Method
- Quantitative
- Specificity
- This assay has high sensitivity and excellent specificity for detection of Minichromosome Maintenance Deficient 3 (MCM3). No significant cross-reactivity or interference between Minichromosome Maintenance Deficient 3 (MCM3) and analogues was observed.
- Sensitivity
- 0.058 ng/mL
- Featured
- Discover our best selling MCM3 ELISA Kit
- Top Product
- Discover our top product MCM3 ELISA Kit
-
-
- Comment
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Assay Time
- 3 h
- Plate
- Pre-coated
- Protocol
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Minichromosome Maintenance Deficient 3 (MCM3). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Minichromosome Maintenance Deficient 3 (MCM3). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Minichromosome Maintenance Deficient 3 (MCM3), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Minichromosome Maintenance Deficient 3 (MCM3) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Minichromosome Maintenance Deficient 3 (MCM3) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Minichromosome Maintenance Deficient 3 (MCM3) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Handling Advice
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Storage
- 4 °C,-20 °C
- Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Expiry Date
- 4-8 months
-
- Target See all MCM3 ELISA Kits
- MCM3 (Minichromosome Maintenance Complex Component 3 (MCM3))
- Alternative Name
- Minichromosome Maintenance Deficient 3 (MCM3 Products)
- Synonyms
- HCC5 ELISA Kit, P1-MCM3 ELISA Kit, P1.h ELISA Kit, RLFB ELISA Kit, AL033361 ELISA Kit, C80350 ELISA Kit, Mcmd ELISA Kit, P1 ELISA Kit, p1.m ELISA Kit, cb32 ELISA Kit, chunp6867 ELISA Kit, wu:fa26g03 ELISA Kit, CG4206 ELISA Kit, DmMCM3 ELISA Kit, DmMcm3 ELISA Kit, DmeMCM3 ELISA Kit, Dmel\\CG4206 ELISA Kit, MCM3 ELISA Kit, McM3 ELISA Kit, Mcp-PCR2 ELISA Kit, PCR2 ELISA Kit, dMCM3 ELISA Kit, xmcm3 ELISA Kit, minichromosome maintenance complex component 3 ELISA Kit, MCM3 minichromosome maintenance deficient 3 (S. cerevisiae) ELISA Kit, Minichromosome maintenance 3 ELISA Kit, minichromosome maintenance complex component 3 L homeolog ELISA Kit, MCM complex subunit Mcm3 ELISA Kit, MCM3 ELISA Kit, mcm3 ELISA Kit, Mcm3 ELISA Kit, mcm3.L ELISA Kit
- Background
-
Gene Name: Minichromosome Maintenance Deficient 3
Gene Aliases: HCC5, P1-MCM3, P1.h, RLFB, RLF subunit beta, DNA replication licensing factor MCM3, DNA polymerase alpha holoenzyme-associated protein P1
- Gene ID
- 4172
- UniProt
- P25205
- Pathways