KLF15 ELISA Kit
-
- Target See all KLF15 ELISA Kits
- KLF15 (Kruppel-Like Factor 15 (KLF15))
-
Reactivity
- Human
- Detection Method
- Colorimetric
- Method Type
- Sandwich ELISA
- Detection Range
- 0.156 ng/mL - 10 ng/mL
- Minimum Detection Limit
- 0.156 ng/mL
- Application
- ELISA
- Sample Type
- Cell Lysate, Tissue Homogenate
- Analytical Method
- Quantitative
- Specificity
- This assay has high sensitivity and excellent specificity for detection of Kruppel Like Factor 15 (KLF15). No significant cross-reactivity or interference between Kruppel Like Factor 15 (KLF15) and analogues was observed.
- Sensitivity
- 0.068 ng/mL
- Featured
- Discover our best selling KLF15 ELISA Kit
- Top Product
- Discover our top product KLF15 ELISA Kit
-
-
- Comment
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Assay Time
- 3 h
- Plate
- Pre-coated
- Protocol
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Kruppel Like Factor 15 (KLF15). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Kruppel Like Factor 15 (KLF15). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Kruppel Like Factor 15 (KLF15), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Kruppel Like Factor 15 (KLF15) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Kruppel Like Factor 15 (KLF15) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Kruppel Like Factor 15 (KLF15) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Handling Advice
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Storage
- 4 °C,-20 °C
- Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Expiry Date
- 4-8 months
-
- Target See all KLF15 ELISA Kits
- KLF15 (Kruppel-Like Factor 15 (KLF15))
- Alternative Name
- Kruppel Like Factor 15 (KLF15 Products)
- Synonyms
- KKLF ELISA Kit, 1810013I09Rik ELISA Kit, AV048136 ELISA Kit, AW494632 ELISA Kit, CKLF ELISA Kit, Kruppel like factor 15 ELISA Kit, Kruppel-like factor 15 S homeolog ELISA Kit, Kruppel-like factor 15 ELISA Kit, KLF15 ELISA Kit, klf15.S ELISA Kit, Klf15 ELISA Kit
- Background
-
Gene Name: Kruppel Like Factor 15
Gene Aliases: KKLF, Kidney-Enriched Kruppel-Like Factor
- Gene ID
- 28999
- UniProt
- Q9UIH9
-