Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

IL17B CLIA Kit

IL17B Reactivity: Human Chemiluminescent Sandwich ELISA 15.62 pg/mL - 1000 pg/mL Plasma, Serum
Catalog No. ABIN5655815
  • Target See all IL17B CLIA Kits
    IL17B (Interleukin 17B (IL17B))
    Reactivity
    • 4
    • 4
    • 3
    Human
    Detection Method
    Chemiluminescent
    Method Type
    Sandwich ELISA
    Detection Range
    15.62 pg/mL - 1000 pg/mL
    Minimum Detection Limit
    15.62 pg/mL
    Application
    ELISA
    Sample Type
    Plasma, Serum
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of Interleukin 17B (IL17B). No significant cross-reactivity or interference between Interleukin 17B (IL17B) and analogues was observed.
    Sensitivity
    0.52 pg/mL
    Top Product
    Discover our top product IL17B ELISA Kit
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time
    2 - 3 h
    Plate
    Pre-coated
    Protocol
    The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 17B (IL17B). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 17B (IL17B). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 17B (IL17B) level in the sample or standard.,
    Assay Precision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 17B (IL17B) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 17B (IL17B) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Restrictions
    For Research Use only
  • Handling Advice
    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Storage
    4 °C,-20 °C
    Storage Comment
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Expiry Date
    4-8 months
  • Target See all IL17B CLIA Kits
    IL17B (Interleukin 17B (IL17B))
    Alternative Name
    Interleukin 17B (IL17B Products)
    Synonyms
    il-17b CLIA Kit, il-20 CLIA Kit, zcyto7 CLIA Kit, IL17B CLIA Kit, IL-17B CLIA Kit, IL-20 CLIA Kit, NIRF CLIA Kit, ZCYTO7 CLIA Kit, 1110006O16Rik CLIA Kit, 1700006N07Rik CLIA Kit, Zcyto7 CLIA Kit, interleukin 17B CLIA Kit, interleukin 17B L homeolog CLIA Kit, IL17B CLIA Kit, il17b CLIA Kit, il17b.L CLIA Kit, Il17b CLIA Kit
    Background

    Gene Name: Interleukin 17B

    Gene Aliases: IL-20, Cytokine Zcyto7, Neuronal interleukin-17-related factor

    Gene ID
    27190
    UniProt
    Q9UHF5
You are here: