Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

IFNA4 CLIA Kit

IFNa4 Reactivity: Human Chemiluminescent Sandwich ELISA 31.25 pg/mL - 2000 pg/mL Plasma, Serum
Catalog No. ABIN5655570
  • Target See all IFNA4 (IFNa4) CLIA Kits
    IFNA4 (IFNa4) (Interferon, alpha 4 (IFNa4))
    Reactivity
    • 3
    • 1
    Human
    Detection Method
    Chemiluminescent
    Method Type
    Sandwich ELISA
    Detection Range
    31.25 pg/mL - 2000 pg/mL
    Minimum Detection Limit
    31.25 pg/mL
    Application
    ELISA
    Sample Type
    Plasma, Serum
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of Interferon Alpha 4 (IFNa4). No significant cross-reactivity or interference between Interferon Alpha 4 (IFNa4) and analogues was observed.
    Sensitivity
    1.26 pg/mL
    Top Product
    Discover our top product IFNa4 ELISA Kit
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time
    2 - 3 h
    Plate
    Pre-coated
    Protocol
    The microplate provided in this kit has been pre-coated with an antibody specific to Interferon Alpha 4 (IFNa4). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interferon Alpha 4 (IFNa4). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interferon Alpha 4 (IFNa4) level in the sample or standard.,
    Assay Precision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interferon Alpha 4 (IFNa4) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interferon Alpha 4 (IFNa4) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Restrictions
    For Research Use only
  • Handling Advice
    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Storage
    4 °C,-20 °C
    Storage Comment
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Expiry Date
    4-8 months
  • Target See all IFNA4 (IFNa4) CLIA Kits
    IFNA4 (IFNa4) (Interferon, alpha 4 (IFNa4))
    Alternative Name
    Interferon Alpha 4 (IFNa4 Products)
    Synonyms
    IFN-alpha4a CLIA Kit, INFA4 CLIA Kit, Ifa4 CLIA Kit, interferon alpha 4 CLIA Kit, interferon, alpha 4 CLIA Kit, interferon-alpha-4 CLIA Kit, IFNA4 CLIA Kit, Ifna4 CLIA Kit, LOC100052921 CLIA Kit
    Background

    Gene Name: Interferon Alpha 4

    Gene Aliases: INFA4, Interferon Alpha-4B, Interferon Alpha-76, Interferon Alpha-M1

    UniProt
    P05014
    Pathways
    JAK-STAT Signaling, Hepatitis C
You are here:
Support