Phone:
+1 877 302 8632
Fax:
+1 888 205 9894 (Toll-free)
E-Mail:
orders@antibodies-online.com

Fission 1 ELISA Kit

FIS1 Reactivity: Human Colorimetric Sandwich ELISA 0.312 ng/mL - 20 ng/mL Cell Lysate, Tissue Homogenate
Catalog No. ABIN5654354
  • Target See all Fission 1 (FIS1) ELISA Kits
    Fission 1 (FIS1)
    Reactivity
    • 1
    • 1
    Human
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    0.312 ng/mL - 20 ng/mL
    Minimum Detection Limit
    0.312 ng/mL
    Application
    ELISA
    Sample Type
    Cell Lysate, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of Fission 1 (FIS1). No significant cross-reactivity or interference between Fission 1 (FIS1) and analogues was observed.
    Sensitivity
    0.115 ng/mL
    Top Product
    Discover our top product FIS1 ELISA Kit
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time
    3 h
    Plate
    Pre-coated
    Protocol
    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Fission 1 (FIS1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Fission 1 (FIS1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Fission 1 (FIS1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Fission 1 (FIS1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
    Assay Precision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fission 1 (FIS1) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fission 1 (FIS1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Restrictions
    For Research Use only
  • Handling Advice
    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Storage
    4 °C,-20 °C
    Storage Comment
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Expiry Date
    4-8 months
  • Target See all Fission 1 (FIS1) ELISA Kits
    Fission 1 (FIS1)
    Alternative Name
    Fission 1 (FIS1 Products)
    Synonyms
    TTC11 ELISA Kit, 2010003O14Rik ELISA Kit, Ttc11 ELISA Kit, fission, mitochondrial 1 ELISA Kit, FIS1 ELISA Kit, Fis1 ELISA Kit
    Background

    Gene Name: Fission 1

    Gene Aliases: CGI-135, TTC11, Tetratricopeptide Repeat Domain 11, Mitochondrial fission 1 protein

    Gene ID
    51024
    UniProt
    Q9Y3D6
    Pathways
    Positive Regulation of Endopeptidase Activity
You are here:
Support