FCN1 CLIA Kit
-
- Target See all FCN1 CLIA Kits
- FCN1 (Ficolin (Collagen/fibrinogen Domain Containing) 1 (FCN1))
-
Reactivity
- Rat
- Detection Method
- Chemiluminescent
- Method Type
- Sandwich ELISA
- Detection Range
- 0.781 ng/mL - 50 ng/mL
- Minimum Detection Limit
- 0.781 ng/mL
- Application
- ELISA
- Sample Type
- Plasma, Serum
- Analytical Method
- Quantitative
- Specificity
- This assay has high sensitivity and excellent specificity for detection of Ficolin 1 (FCN1). No significant cross-reactivity or interference between Ficolin 1 (FCN1) and analogues was observed.
- Sensitivity
- 0.03 ng/mL
- Top Product
- Discover our top product FCN1 ELISA Kit
-
-
- Comment
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Assay Time
- 2 - 3 h
- Plate
- Pre-coated
- Protocol
- The microplate provided in this kit has been pre-coated with an antibody specific to Ficolin 1 (FCN1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Ficolin 1 (FCN1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Ficolin 1 (FCN1) level in the sample or standard.,
- Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ficolin 1 (FCN1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ficolin 1 (FCN1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Handling Advice
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Storage
- 4 °C,-20 °C
- Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Expiry Date
- 4-8 months
-
- Target See all FCN1 CLIA Kits
- FCN1 (Ficolin (Collagen/fibrinogen Domain Containing) 1 (FCN1))
- Alternative Name
- Ficolin 1 (FCN1 Products)
- Synonyms
- FCNM CLIA Kit, FCNB CLIA Kit, FCN2 CLIA Kit, FCN1 CLIA Kit, ficolin 1 CLIA Kit, ficolin (collagen/fibrinogen domain containing) 1 CLIA Kit, ficolin-1 CLIA Kit, FCN1 CLIA Kit, Fcn1 CLIA Kit, LOC100069029 CLIA Kit
- Background
-
Gene Name: Ficolin 1
Gene Aliases: FCNM, Collagen/fibrinogen domain-containing protein 1, Ficolin-alpha, Ficolin-A, M-ficolin
- UniProt
- Q9WTS8
- Pathways
- Complement System
-