DIDO1 ELISA Kit

DIDO1 Reactivity: Human Colorimetric Sandwich ELISA 0.312 ng/mL - 20 ng/mL Tissue Homogenate
Catalog No. ABIN5653558
  • Target See all DIDO1 ELISA Kits
    DIDO1 (Death Inducer-Obliterator 1 (DIDO1))
    Reactivity
    • 3
    • 3
    • 1
    Human
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    0.312 ng/mL - 20 ng/mL
    Minimum Detection Limit
    0.312 ng/mL
    Application
    ELISA
    Sample Type
    Tissue Homogenate
    Analytical Method
    Quantitative
    Specificity
    This assay has high sensitivity and excellent specificity for detection of Death Inducer Obliterator 1 (DIDO1). No significant cross-reactivity or interference between Death Inducer Obliterator 1 (DIDO1) and analogues was observed.
    Sensitivity
    0.104 ng/mL
    Featured
    Discover our best selling DIDO1 ELISA Kit
    Top Product
    Discover our top product DIDO1 ELISA Kit
  • Comment

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Assay Time
    3 h
    Plate
    Pre-coated
    Protocol
    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Death Inducer Obliterator 1 (DIDO1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Death Inducer Obliterator 1 (DIDO1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Death Inducer Obliterator 1 (DIDO1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Death Inducer Obliterator 1 (DIDO1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
    Assay Precision
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Death Inducer Obliterator 1 (DIDO1) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Death Inducer Obliterator 1 (DIDO1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Restrictions
    For Research Use only
  • Handling Advice
    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Storage
    4 °C,-20 °C
    Storage Comment
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Expiry Date
    4-8 months
  • Target See all DIDO1 ELISA Kits
    DIDO1 (Death Inducer-Obliterator 1 (DIDO1))
    Alternative Name
    Death Inducer Obliterator 1 (DIDO1 Products)
    Background

    Gene Name: Death Inducer Obliterator 1

    Gene Aliases: BYE1, DATF1, DIDO2, DIDO3, DIO1, Death Associated Transcription Factor 1

    Gene ID
    11083
    UniProt
    Q9BTC0
    Pathways
    Hormone Activity
You are here:
Support