DAOA CLIA Kit
-
- Target See all DAOA products
- DAOA (D-Amino Acid Oxidase Activator (DAOA))
- Reactivity
- Human
- Detection Method
- Chemiluminescent
- Method Type
- Sandwich ELISA
- Detection Range
- 156.25 pg/mL - 10000 pg/mL
- Minimum Detection Limit
- 156.25 pg/mL
- Application
- ELISA
- Sample Type
- Tissue Homogenate
- Analytical Method
- Quantitative
- Specificity
- This assay has high sensitivity and excellent specificity for detection of D-amino Acid Oxidase Activator (DAOA). No significant cross-reactivity or interference between D-amino Acid Oxidase Activator (DAOA) and analogues was observed.
- Sensitivity
- 6.49 pg/mL
- Featured
- Discover our best selling DAOA ELISA Kit
-
-
- Comment
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Assay Time
- 2 - 3 h
- Plate
- Pre-coated
- Protocol
- The microplate provided in this kit has been pre-coated with an antibody specific to D-amino Acid Oxidase Activator (DAOA). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to D-amino Acid Oxidase Activator (DAOA). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the D-amino Acid Oxidase Activator (DAOA) level in the sample or standard.,
- Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level D-amino Acid Oxidase Activator (DAOA) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level D-amino Acid Oxidase Activator (DAOA) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Handling Advice
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Storage
- 4 °C,-20 °C
- Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Expiry Date
- 4-8 months
-
- Target See all DAOA products
- DAOA (D-Amino Acid Oxidase Activator (DAOA))
- Alternative Name
- D-amino Acid Oxidase Activator (DAOA Products)
- Background
-
Gene Name: D-amino Acid Oxidase Activator
Gene Aliases: G72, LG72, SG72
-