CLCF1 CLIA Kit
-
- Target See all CLCF1 CLIA Kits
- CLCF1 (Cardiotrophin-Like Cytokine Factor 1 (CLCF1))
-
Reactivity
- Human
- Detection Method
- Chemiluminescent
- Method Type
- Sandwich ELISA
- Detection Range
- 62.5 pg/mL - 4000 pg/mL
- Minimum Detection Limit
- 62.5 pg/mL
- Application
- ELISA
- Sample Type
- Plasma, Serum
- Analytical Method
- Quantitative
- Specificity
- This assay has high sensitivity and excellent specificity for detection of Cardiotrophin Like Cytokine Factor 1 (CLCF1). No significant cross-reactivity or interference between Cardiotrophin Like Cytokine Factor 1 (CLCF1) and analogues was observed.
- Sensitivity
- 2.57 pg/mL
- Featured
- Discover our best selling CLCF1 ELISA Kit
- Top Product
- Discover our top product CLCF1 ELISA Kit
-
-
- Comment
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Assay Time
- 2 - 3 h
- Plate
- Pre-coated
- Protocol
- The microplate provided in this kit has been pre-coated with an antibody specific to Cardiotrophin Like Cytokine Factor 1 (CLCF1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Cardiotrophin Like Cytokine Factor 1 (CLCF1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Cardiotrophin Like Cytokine Factor 1 (CLCF1) level in the sample or standard.,
- Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cardiotrophin Like Cytokine Factor 1 (CLCF1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cardiotrophin Like Cytokine Factor 1 (CLCF1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Handling Advice
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Storage
- 4 °C,-20 °C
- Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Expiry Date
- 4-8 months
-
- Target See all CLCF1 CLIA Kits
- CLCF1 (Cardiotrophin-Like Cytokine Factor 1 (CLCF1))
- Alternative Name
- Cardiotrophin Like Cytokine Factor 1 (CLCF1 Products)
- Synonyms
- clc CLIA Kit, nr6 CLIA Kit, bsf3 CLIA Kit, nnt1 CLIA Kit, ciss2 CLIA Kit, CLCF1 CLIA Kit, BSF-3 CLIA Kit, BSF3 CLIA Kit, CISS2 CLIA Kit, CLC CLIA Kit, NNT-1 CLIA Kit, NNT1 CLIA Kit, NR6 CLIA Kit, Bsf3 CLIA Kit, Clc CLIA Kit, cardiotrophin like cytokine factor 1 CLIA Kit, cardiotrophin-like cytokine factor 1 CLIA Kit, clcf1 CLIA Kit, CLCF1 CLIA Kit, Clcf1 CLIA Kit
- Background
-
Gene Name: Cardiotrophin Like Cytokine Factor 1
Gene Aliases: CLC, NR6, BSF3, CISS2, NNT1, Novel Neurotrophin-1, B Cell-Stimulating Factor-3
- Gene ID
- 23529
- UniProt
- Q9UBD9
- Pathways
- Regulation of Leukocyte Mediated Immunity, Positive Regulation of Immune Effector Process, Production of Molecular Mediator of Immune Response
-