BIN1 ELISA Kit
-
- Target See all BIN1 ELISA Kits
- BIN1 (Bridging Integrator 1 (BIN1))
-
Reactivity
- Human
- Detection Method
- Colorimetric
- Method Type
- Sandwich ELISA
- Detection Range
- 0.156 ng/mL - 10 ng/mL
- Minimum Detection Limit
- 0.156 ng/mL
- Application
- ELISA
- Sample Type
- Plasma, Serum, Tissue Homogenate
- Analytical Method
- Quantitative
- Specificity
- This assay has high sensitivity and excellent specificity for detection of Bridging Integrator 1 (BIN1). No significant cross-reactivity or interference between Bridging Integrator 1 (BIN1) and analogues was observed.
- Sensitivity
- 0.061 ng/mL
- Featured
- Discover our best selling BIN1 ELISA Kit
- Top Product
- Discover our top product BIN1 ELISA Kit
-
-
- Comment
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Assay Time
- 3 h
- Plate
- Pre-coated
- Protocol
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Bridging Integrator 1 (BIN1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Bridging Integrator 1 (BIN1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Bridging Integrator 1 (BIN1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Bridging Integrator 1 (BIN1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Bridging Integrator 1 (BIN1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Bridging Integrator 1 (BIN1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Handling Advice
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Storage
- 4 °C,-20 °C
- Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Expiry Date
- 4-8 months
-
- Target See all BIN1 ELISA Kits
- BIN1 (Bridging Integrator 1 (BIN1))
- Alternative Name
- Bridging Integrator 1 (BIN1 Products)
- Synonyms
- bin1 ELISA Kit, MGC53185 ELISA Kit, amph2 ELISA Kit, amphl ELISA Kit, sh3p9 ELISA Kit, MGC76187 ELISA Kit, cb57 ELISA Kit, zgc:86701 ELISA Kit, BIN1 ELISA Kit, AMPH2 ELISA Kit, AMPHL ELISA Kit, SH3P9 ELISA Kit, ALP-1 ELISA Kit, Amphl ELISA Kit, BRAMP-2 ELISA Kit, bridging integrator 1 ELISA Kit, bridging integrator 1 S homeolog ELISA Kit, bridging integrator 1b ELISA Kit, BIN1 ELISA Kit, bin1.S ELISA Kit, bin1 ELISA Kit, bin1b ELISA Kit, Bin1 ELISA Kit
- Background
-
Gene Name: Bridging Integrator 1
Gene Aliases: AMPH2, AMPHL, SH3P9, Amphiphysin II, Myc Box-Dependent-Interacting Protein 1, Amphiphysin-like protein
- Gene ID
- 274
- UniProt
- O00499
-