beta-Thromboglobulin CLIA Kit
-
- Target See all beta-Thromboglobulin (beta-TG) CLIA Kits
- beta-Thromboglobulin (beta-TG)
-
Reactivity
- Rat
- Detection Method
- Chemiluminescent
- Method Type
- Sandwich ELISA
- Detection Range
- 11.72 pg/mL - 3000 pg/mL
- Minimum Detection Limit
- 11.72 pg/mL
- Application
- ELISA
- Sample Type
- Plasma
- Analytical Method
- Quantitative
- Specificity
- This assay has high sensitivity and excellent specificity for detection of Beta-Thromboglobulin (bTG). No significant cross-reactivity or interference between Beta-Thromboglobulin (bTG) and analogues was observed.
- Sensitivity
- 1.71 pg/mL
- Featured
- Discover our best selling beta-TG ELISA Kit
- Top Product
- Discover our top product beta-TG ELISA Kit
-
-
- Comment
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Assay Time
- 2 - 3 h
- Plate
- Pre-coated
- Protocol
- The microplate provided in this kit has been pre-coated with an antibody specific to Beta-Thromboglobulin (bTG). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Beta-Thromboglobulin (bTG). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Beta-Thromboglobulin (bTG) level in the sample or standard.,
- Assay Precision
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Beta-Thromboglobulin (bTG) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Beta-Thromboglobulin (bTG) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Handling Advice
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Storage
- 4 °C,-20 °C
- Storage Comment
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Expiry Date
- 4-8 months
-
- Target See all beta-Thromboglobulin (beta-TG) CLIA Kits
- beta-Thromboglobulin (beta-TG)
- Alternative Name
- Beta-Thromboglobulin (beta-TG Products)
- Synonyms
- B-TG1 CLIA Kit, Beta-TG CLIA Kit, CTAP-III CLIA Kit, CTAP3 CLIA Kit, CTAPIII CLIA Kit, CXCL7 CLIA Kit, LA-PF4 CLIA Kit, LDGF CLIA Kit, MDGF CLIA Kit, NAP-2 CLIA Kit, PBP CLIA Kit, SCYB7 CLIA Kit, TC1 CLIA Kit, TC2 CLIA Kit, TGB CLIA Kit, TGB1 CLIA Kit, THBGB CLIA Kit, THBGB1 CLIA Kit, CTAPIII/NAP-2 CLIA Kit, 2400003M24Rik CLIA Kit, AI854500 CLIA Kit, Cxcl7 CLIA Kit, NAP-2-L1 CLIA Kit, Scyb7 CLIA Kit, b-TG1 CLIA Kit, beta-TG CLIA Kit, Nap-2 CLIA Kit, pro-platelet basic protein CLIA Kit, PPBP CLIA Kit, Ppbp CLIA Kit
- Background
-
Gene Name: Beta-Thromboglobulin
Gene Aliases: CXCL7, PPBP, PBP, B-TG1, CTAP-III, CTAP3, CTAPIII, LA-PF4, LDGF, MDGF, NAP2, SCYB7, TC1, TC2, TGB1, THBGB1, Pro-Platelet Basic Protein, Chemokine C-X-C-Motif Ligand 7
- Gene ID
- 246358
- UniProt
- Q99ME0
-