AMACR ELISA Kit

AMACR Reactivity: Rat Colorimetric Sandwich ELISA 62.5-4000 pg/mL Plasma, Serum
Catalog No. ABIN4993314
  • Target See all AMACR ELISA Kits
    AMACR (alpha-Methylacyl-CoA Racemase (AMACR))
    Reactivity
    • 3
    • 1
    Rat
    Detection Method
    Colorimetric
    Method Type
    Sandwich ELISA
    Detection Range
    62.5-4000 pg/mL
    Minimum Detection Limit
    62.5 pg/mL
    Application
    ELISA
    Purpose
    The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of AMACR in Rat serum, plasma and other biological fluids
    Sample Type
    Plasma, Serum
    Analytical Method
    Quantitative
    Specificity
    This kit recognizes natural and recombinantRatAMACR. No significant cross-reactivity or interference between RatAMACR and analogues was observed. Note: Limited by existing techniques, cross reaction may still exist, as it is impossible for us to complete the cross-reactivity detection between RatAMACR and all the analogues.
    Sensitivity
    37.5 pg/mL
    Components
    Micro ELISA Plate
    Reference Standard
    Concentrated Biotinylated Detection Ab
    Concentrated HRP Conjugate
    Reference Standard & Sample Diluent
    Biotinylated Detection Ab Diluent
    HRP Conjugate Diluent
    Concentrated Wash Buffer (25×)
    Substrate Reagent
    Stop Solutio
    Plate Sealer
    Product Description
    Certificate of Analysis
    Material not included
    Microplate reader with 450nm wavelength filter
    High-precision transferpettor, EP tubes and disposable pipette tips
    37℃ Incubator
    Deionized or distilled water
    Absorbent paper
    Loading slot for Wash Buffer
    Top Product
    Discover our top product AMACR ELISA Kit
  • Comment

    Information on standard material:
    The formulation of the standard is 0.01 M PBS. The standard contains additives (1 % BSA).

    Information on reagents:
    Reagents include 1 M SO2. Azide, thimerosal, 2-mercaptoethanol (2-ME) or any other poisonous materials are not used.

    Information on antibodies:
    The provided antibodies and their host vary in different kits. All antibodies are affinity purified

    The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined by adding two standard deviations to the mean optical density value of twenty zero standard replicates and calculating the corresponding concentration.

    Sample Volume
    100 µL
    Plate
    Pre-coated
    Protocol
    This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to AMACR. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for AMACRand Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain AMACR, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of AMACR.You can calculate the concentration of AMACRin the samples by comparing the OD of the samples to the standard curve. 6th Edition, revised in June, 2015 www.elabscience.com 4
    Restrictions
    For Research Use only
  • Handling Advice
    All the reagents in the kit should be stored according to the labels on vials. Unused wells should be returned to the foil pouch with the desiccant pack and resealed along entire edge of zip-seal. Substrate Reagent shouldn't be kept at -20 °C (Check!). Exposure of reagents to strong light should be avoided in the process of incubation and storage. All the taps of reagents should be tightened to prevent evaporation and microbial contamination. If not to store reagents according to above suggestions, erroneous results may occur.
    Storage
    4 °C/-20 °C
    Storage Comment
    The unopened kit can be stored at 4℃ for 1 month. If the kit is not used within 1 month, store the items separately according to the conditions since the kit is received.
  • Target See all AMACR ELISA Kits
    AMACR (alpha-Methylacyl-CoA Racemase (AMACR))
    Abstract
    AMACR Products
    Synonyms
    AMACR ELISA Kit, DKFZp469O1232 ELISA Kit, amacr ELISA Kit, NCU04099.1 ELISA Kit, MGC89832 ELISA Kit, AMACRD ELISA Kit, CBAS4 ELISA Kit, RACE ELISA Kit, RM ELISA Kit, Macr1 ELISA Kit, Da1-8 ELISA Kit, Marc1 ELISA Kit, alpha-methylacyl-CoA racemase ELISA Kit, PROBABLE ALPHA-METHYLACYL-COA RACEMASE MCR (2-methylacyl-CoA racemase) (2-arylpropionyl-CoA epimerase) ELISA Kit, Alpha-methylacyl-CoA racemase ELISA Kit, alpha-methylacyl-CoA racemase L homeolog ELISA Kit, AMACR ELISA Kit, mcr ELISA Kit, BPSL0064 ELISA Kit, Maqu_2037 ELISA Kit, UREG_03852 ELISA Kit, MCYG_01809 ELISA Kit, amacr ELISA Kit, amacr.L ELISA Kit, MGYG_04259 ELISA Kit, NCU04099 ELISA Kit, Amacr ELISA Kit
    Pathways
    Monocarboxylic Acid Catabolic Process