ERCC1 ELISA Kit
-
- Target See all ERCC1 ELISA Kits
- ERCC1 (Excision Repair Cross Complementing Polypeptide-1 (ERCC1))
-
Reactivity
- Human
- Detection Method
- Colorimetric
- Method Type
- Sandwich ELISA
- Detection Range
- 0.156 ng/mL - 10 ng/mL
- Minimum Detection Limit
- 0.156 ng/mL
- Application
- ELISA
- Purpose
-
Human ERCC1 ELISA Kit is a sandwich ELISA kit for use with Tissue homogenates, cell lysates and other biological fluids. This assay has high sensitivity and excellent specificity for detection of Excision Repair Cross Complementing Rodent Repair Deficiency Complementation 1 (ERCC1)
No significant cross-reactivity or interference between Excision Repair Cross Complementing Rodent Repair Deficiency Complementation 1 (ERCC1) and analogues was observed. - Sample Type
- Cell Lysate, Tissue Homogenate
- Analytical Method
- Quantitative
- Specificity
- This assay has high sensitivity and excellent specificity for detection of Excision Repair Cross Complementing Rodent Repair Deficiency Complementation 1 (ERCC1)
- Sensitivity
- < 0.054 ng/mL
- Featured
- Discover our best selling ERCC1 ELISA Kit
- Top Product
- Discover our top product ERCC1 ELISA Kit
-
-
- Application Notes
-
Stability: The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5 % within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.
Recommended dilutions: Optimal dilutions/concentrations should be determined by the end user.
Standard Form: Lyophilized
- Comment
-
The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5% within the expiration date under appropriate storage conditions. - minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.
- Plate
- Pre-coated
- Restrictions
- For Research Use only
-
- Storage
- 4 °C/-20 °C
- Storage Comment
- Upon receipt, store the kit according to the storage instruction in the kit's manual.
- Expiry Date
- 6 months
-
- Target See all ERCC1 ELISA Kits
- ERCC1 (Excision Repair Cross Complementing Polypeptide-1 (ERCC1))
- Alternative Name
- ERCC1 (ERCC1 Products)
- Pathways
- DNA Damage Repair, Production of Molecular Mediator of Immune Response
-